My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0746
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0746
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:40:57 PM
Creation date
10/27/2006 2:16:39 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0746
Building Department - Name
DAVIS CONST
Address
4840 TIMBER WY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />1 "-'I 'IVI VVVr-\-'Io"I1 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:, Zephyrhills, FL, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior WindCJNS & Doors 606,1.ABC.1,1 Maximum:.3 cfmlsa.ft. window area' ,5 cfmlsa.ft, door area. <br />Exterior & Adjacent Walls 606,1 ,ABC.1 ,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & topIbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the too olate. <br />Floors 606,1.ABC,1,2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter oenetrations and seams. <br />Ceilings 606,1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the oerimeter at oenetrations and seams. <br />Recessed Ughting Fixtures 606.1.ABC .1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br /> conditioned soace tested. <br />Multi-storv Houses 606,1.ABC.1.2.5 Air barrier on oerimeter of floor cavity between floors. <br />.Additionallnfiltratjon reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> halle combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-1.2, Switch or clearly marked circuit <br /> breaker (electric) or cutoff (aas) must be orovided, External or built~in heat trao reauired, <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated), Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiency of 78%. <br />Shower heads 612,1 Water flow must be restricted to no more than 2,5 aallons oer minute at 80 PSIG. <br />Air Distribution Systems 610,1 All ducts, fittings; mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulall!ld, $I'Id installed in accordance with the criteria of Section 610. <br /> Ducts in unconditiOlllid attics: R-6 mill. insulation, <br />HVAC Controls 607,1 Seoarate readilv accessible manual or automatic thermostat for each sYStem. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19, Common walls-Frame R-11 or CBS R-3 both sides, <br /> Common ceiling & floors R-11. <br /> <br />EnergyGauge TIoI DCA Form 600A-97 <br /> <br />EnergyGauge@lFlaRES'97 FLRCNA-200 <br />
The URL can be used to link to this page
Your browser does not support the video tag.