<br />I ""'I ll.IV. VVV~-lwi"
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />Florida Department of Community Affairs
<br />Residential Whole Building Performance Method A
<br />
<br /> .
<br />Project Name: J,.t:n 10 JDavis C3vTJ...E'~ Builder: Davis
<br />Address: Permitting Office: Pasco ,
<br />City, State: Zephyrhills, FL Permit Number:
<br />Owner: Davis Jurisdiction Number:
<br />Climate Zone: Central
<br /> ./
<br />1. New construction or existing New ~ 12. Cooling systelDS Cap: 32,6 kBtu/hr ~
<br />2. Single family or multi-family Single family a. Central Unit
<br />3. Number of units, ifmulti-family I ~ SEER: 10.00 _
<br />4, Number ofBedrooDlS 3 b, NJA -
<br />5. Is this a worst case? Yes -
<br />6. Conditioned floor area (1P) 1365 IP ~ c. NJA -
<br />7- Glass area & type -
<br /> ll. Clear - single pane 120,0 1];2 13. Heating systems ~
<br /> b, Clear - double pane 0,0 tt" - a, Electric Heat Pwnp Cap: 33,4 kBtuIhr
<br /> c. Tint/other SCJSHGC - single pane 0.0 ft2 HSPF: 6.80
<br /> -
<br /> d. Tint/other SCISHGC - double pane 0,0 ft2 V b, NJA -
<br />8. Floor types . -
<br /> ll. Slab-On-Grade Edge Insulation R=O,O, l58,O(P) ft 'i! c. NJA -
<br /> b. NJA -
<br /> -
<br /> c. NJA ~ 14. Hot water systems -?
<br />9, Wall types a. Electric Resistance Cap: 40.0 gallons
<br /> a. Concrete, Inr Insul, EA'terior R=5.0, 956.0 112 EF: 0.90
<br /> II -
<br /> b. Frame, Wood, Adjacent R=11.0, 172.01];2 b, NJA -
<br /> c. NJA -
<br /> -
<br /> d. NJA - c, Conservation credits -
<br /> e. NJA ~ (HR.-Heat recovery, Solar
<br />10, Ceiling types DHP-Dedicated heat pwnp)
<br /> ..
<br /> a, Under Attic R=19,O, 1365,0 t12 - 15, HV AC credits -
<br /> b. NJA " (CF-Ceiling fan, CV-Cross ventilation,
<br /> -
<br /> e. NJA ~ HF-Whole house fan,
<br />11. Ducts PT -Programmable Thermostat,
<br /> a. Sup: Une, Ret: Unc, AH: Attic Slip. R=6.0, 100.0 ft RB-Attic radiant barrier,
<br /> b. NJA MZ-C-Multizone cooling,
<br /> MZ-H-Multizone heating)
<br />
<br />Glass/Floor Area: 0,09
<br />
<br />PASS
<br />
<br />Total as-built points: 19584.00
<br />Total base points: 21600.00
<br />
<br />I hereby certify that the plans and specifications covered
<br />by this calculation are in compliance with the Florida
<br />Energy Code.
<br />
<br />PREPARED BY: Shelby R. Carter k
<br />
<br />DATE: /~/z hi'
<br />, ,
<br />I hereby certify that this building, as designed, is in
<br />compliance with the FI~Oida E erg.. YC. od~./ _
<br />OWNER/AGENT: _ _{l~
<br />DATE: /4 z. ~
<br />
<br />BUILDING 0 F IAL:
<br />DATE: J VJ
<br />
<br />
<br />Review of the plans and
<br />specifications covered by this
<br />calculation indicates compliance
<br />with the Florida Energy Code.
<br />Before construction is completed
<br />this building will be inspected for
<br />compliance with Section 553.908
<br />Florida Statutes.
<br />
<br />EnergyGauge<ID (Version: FLRCNA-200)
<br />
|