<br />r-UIl:.M bUUA-l:Il
<br />
<br />FLORIDA a:NERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />
<br />Florida Department of Community Affairs
<br />Residential Whole Building Performance Method A
<br />
<br />SPIIIB Builder: G.H.D. t',..
<br />Lot#l8 Oakcrest Way Pennitting Office: CJ.r 01 Z~ fJ-..'frn; .;.
<br />Zephyrhills, FL Pennit Number: <9 'i' ? 0
<br />Oakcrest Spec Jurisdiction Number: ~ I ( 60 0
<br />Central
<br />
<br />Project Name:
<br />Address:
<br />City, State:
<br />Owner:
<br />Climate Zone:
<br />
<br />1, New construction or existinB
<br />2, Single family or multi-family
<br />3. Nwnber of units, if multi-family
<br />4. Nwnber of Bedrooms
<br />5. Is this a worst cast!?
<br />6, Conditioned floor area (ft2)
<br />7. Olass area & type
<br />a, Clear - single pane
<br />b, Clear - double pane
<br />c. Tint/other SCfSHOC - single pUle
<br />d Tint/other SC/SHOC - double pane
<br />8, Floor types
<br />a. Slab-On-Orade Edge Insulation
<br />b.NlA
<br />c.NlA
<br />9, Will types
<br />a. Concrete, 101 Insu1, Exterior
<br />b,FrlD1e, Wood,P.~aceo1
<br />c,NlA
<br />d.NlA
<br />e, NlA
<br />10. Ceiling types
<br />a. Under Attic
<br />b, Under Attic
<br />c. Under Attic
<br />11 Ducts
<br />a, SUp: Unc, Ret: Unc AH: Oarage
<br />b,NlA
<br />
<br />New
<br />Single family
<br />I
<br />3
<br />No
<br />1200 ft2
<br />
<br />169.8 ft2
<br />0.0 ft2
<br />0,0 ft2
<br />001\2
<br />
<br />R=O,O, 156,8(p) ft
<br />
<br />R=4,J, 881.5 1\2
<br />R=11.0, 166.4 ft2
<br />
<br />R=22,O, 676.0 ft2
<br />R=22,O, 536.0 ft2
<br />R=19.0, 64,0 ft2
<br />
<br />Sup, R=6,O, 100.0 ft
<br />
<br />12, Cooline systems
<br />a Central Unit
<br />
<br />Cap' 28.8 kBtuIhr
<br />SEER: 10,00
<br />
<br />b,NlA
<br />
<br />c NlA
<br />
<br />13, Heating systems
<br />a. FJectric Heat Pump
<br />
<br />Cap: 28.8 kBtuIhr
<br />HSPF: 7,00
<br />
<br />b, NIP.
<br />
<br />c,NlA
<br />
<br />14. Hot water systems
<br />a, FJectric Resistance
<br />
<br />Cap 40.0 gallons
<br />EF: 0.90
<br />
<br />b,N1A
<br />
<br />c, Conservation credits
<br />(HR.-Heat recovery. Solar
<br />DHP.Dedicated heat pump)
<br />15. INAC credits
<br />(CF -Ceiling fan, CV.Cross ventilation,
<br />HF -Whole house fan,
<br />P T -Progrmunable Thermostat,
<br />RB-Attic radimt barrier,
<br />MZ-C-Multizone cooling,
<br />MZ-H-Multizone heating)
<br />
<br />GlassIFloor Area: 0.14
<br />
<br />PASS
<br />
<br />Total as-built points: 18359.00
<br />Total base points: 19876.00
<br />
<br />I hereby certify that the plans and specifications covered
<br />by this calculation are in compliance with the Florida
<br />Energy Code. ,
<br />PREPARED BY: ~/Ji7ffr
<br />DATE: /1 I
<br />I hereby certify that this building, as designed, is in
<br />compliance with the Florida nergy Code.
<br />OWNE~:
<br />DATE:
<br />
<br />
<br />
<br />Review of the plans and
<br />specifications covered by this
<br />calculation indicates compliance
<br />with the Florida Energy Code.
<br />Before construction is completed
<br />this building wil be inspected for
<br />compliance with Section 553.908
<br />Florida Statutes.
<br />
<br />EnergyGaug~ (Version: FLRCNA-200)
<br />
|