Laserfiche WebLink
<br /> <br />FAS- TEL and FAS-31XT <br /> <br />. <br /> <br />RJ~ I RJ31X ~elephoneJrrotectio1 f:- t t . - 1 <br /> <br /> <br />The FAS-TEL and FAS-31XT are single pair Telephone or Data Line Protectors <br />that implement advanced two-stage hybrid design, These units address over volt- <br />age transients with silicon breakover devices, while sneak and fault currents are <br />mitigated with new PTC technology which consists of solid state resettable fuses, <br /> <br />. <br /> <br />FAS-31XT replaces the R131X jack with a protected version. Four screw termi- <br />nals are provided to wire the protector in the same manner as a standard RJ31X <br />jack. The FAS-31XT can be used alone or as an accessory to the TS-500G or TS- <br />500F AC Power Surge Protector. The TS-500G and TS-500F provide a conve- <br />nient grounding point for the FAS-31XT I FAS-TEL ground wire" <br /> <br />The FAS-TEL is nearly identical to the FAS-31XT except without the shorting <br />bars. Two screw terminals are provided to connect Telco Line to protector, <br />Protected equipment such as moderns are plugged into female modular jack <br />on the FAS-TEL. <br /> <br />IIDlm1D <br /> <br />. <1 Nanosecond Response Time <br />. Solid-State Silicon <br /> <br />Breakover Technology <br /> <br />. Low Capacitance <br />. Over Current Protection <br />. UL497A Listed/.-' <br /> <br />. Line-to-Line Protection <br />. Line-to-Ground Protection <br /> <br />. Polys witch Resettable Fuses - PTCs <br /> <br />- <br /> <br />Part Number Max Peak Nominal Max Current Max Clamp Typ Cap Max Continuous Nominal <br /> Signal Breakdown Ip lOXlOOO J.IS Voltage (pO Current Series <br /> Voltage Voltage @Ip Resistance <br />FAS-TEL-015T 12 15 124 20 2100 150ma 8 Ohms <br />FAS-TEL-030T 24 30 71 38 1180 150ma 8 Ohms <br />FAS- TEL-050T 43 50 45 57 900 150ma 8 Ohms <br />FAS-TEL-060T 52 60 36 66 750 150ma 8 Ohms <br />FAS- TEL-200T 220 300 200A (T-G)+(R-G) 10* 100 150ma 8 Ohms <br />FAS-31XT 220 300 200A (T-G)+(R-G) 10 * 100 150ma 8 Ohms <br /> <br />. <br /> <br />* NOTE: Forward Voltage After Breakover <br /> <br />mmDBmm <br />@ <br /> <br />497A <br /> <br />TO PHONE OR COMPlfTER/ <br /> <br /> <br />oIu RJ or IjAB6WIRE <br />PROTECTED /// <br />SIDE I j <br /> <br />FAS-31XT <br /> <br />FAS- TEL <br /> <br />TO ALARM SYSTEM <br /> <br /> <br /> <br />PROTECTED I <br />SIDE . PHONE <br /> <br /> <br /> <br />-+ <br /> <br />Building Approved ground <br /> <br />Building Approved ground <br /> <br />HARDWIRE DIRECTLY FOR <br />NEW ALARM INSTALLATIONS <br /> <br />UNPROTECTED <br /> <br /> <br />SIDE ~ <br /> <br />HARDWIRE <br /> <br />. <br /> <br />OR <br /> <br />OR <br /> <br />USE PROVIDED 2' CORD WITH MALE RJ FOR <br />INSTALLATIONS WITH EXISTING 31X TELEPHONE JACK. <br /> <br />USE PROVIDED 7' <br />CORD WITH MALE RJ <br /> <br />18 <br />