Laserfiche WebLink
<br />ESL 449 Series Smoke Detectors <br /> <br />Architectural and Engineering Specifications <br />The ESL 449 Series low-profile, self-diagnostic, four-wire smoke <br />detectors work on the light scattering principle, A pulsed infrared <br />light-emitting diode serves as the light source, and a high-speed <br />photodiode as the sensing element. When the amount of light <br />reflected onto the photodiode reaches the sensitivity setting, the <br />smoke sampling rate increases. Three (3) successive smoke <br />sensings above the sensitivity setting are required to sound an alarm. <br />This design has superior protection against false alarms caused by <br />dust, insects, RF and ambient-light. <br /> <br />A confirmed alarm causes the normally flashing power indicator LED <br />to light continuously and the alarm relay to operate. A trouble <br />indication is automatically displayed by flashing the LED every <br />second. This meets NFPA 72 field sensitivity testing requirements, <br />An internal 85 dB horn (available in "S" models) emits a steady tone <br />when the detector alarms and a pulsed tone when power polarity is <br />reversed. <br /> <br />Product Data <br />Sensitivity....,...,..............,......,..............,.., 3.1 - 1,O%/f1. (max.) <br />3,1 + O,50%/ft, (min) <br />Operating temp, range .......,.... 320F to 1200F (OOC to 50oC) <br />Operating humidity range .........,...,.........,........, 0 to 95% RH <br />Minimum voltage - C, CT, CRT, CST, CSRT, CSST, CSRH, . <br />CTE, CL T, CSL T, CSTE .....,..,..,........,...........,..,..,..., 8,5 V <br /> <br />_ AT ........,..........,.......,......,.......,......,....,........,.............. 5,1 V <br />Maximum voltage - C, CT, CRT, CST, CSRT, CSST, CSRH, <br />CTE, CLT, CSLT, CSTE .......,...............,....,.........,...., 33 V <br /> <br />_ AT ...........,....,..,...,..,........,.......,......,..,..........,...........,.. 27 V <br />Maximum ripple (peak to peak) ,.,..........,......................, 10% <br />Typical average standby current ,....,.....,..,.......,...,...... 70 JlA <br /> <br />_ CTE, CSTE ............,....,..........,...,......,..,.....,....,.......,.. 25MA <br />Typical alarm current - C, CT and AT .........,......,..,..., 15 mA <br /> <br />_ CRT ,.......,.,.,..........,..........,..,......,....,.......,............ 31 mA <br /> <br />Selection Guide <br /> <br />The proprietary optical sensing chamber is field replaceable, allowing <br />quick and easy cleaning and maintenance, <br />Models with auxiliary relays are approved for releasing service. <br />This low profile product is equipped with a hinged cover, a concealed <br />tamper-resistant latch, and insect screens, <br />Wiring terminates in plug-in, clamp-type screw terminals. Detectors <br />mount to a standard single-gang electrical box, a four-inch octago- <br />nal, four-inch square electrical box, or WIREMOLD 5739 fixture box. <br /> <br />Smoke Detector Spacing <br />On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9,1 meters) <br />may be used as a guide, Other spacing may be used depending on ceiling <br />height, high air movement, and other conditions or response requirements. <br /> <br />185';&:;1~ 61,J5""1~ <br />1== LV <br /> <br />_ CST and CSST..........,.........,......,....,...,................ 40 mA <br />_ CSRT, CSRH, CSTE .....,...,.......,..........,....,..,....... 51 mA <br />Typical avg, polarity reverse current <br />_ CST, CSRT, CSST, CSLT, CSTE, AND CSRH ..,.. 10 mA <br />Sounder specifications ......,..........,......,...,...... 85 dB at 10 ft. <br />Heat detector specifications <br />_ fixed temperature ......,.....,.......,..,............ 1350F (57.20C) <br />_ r.ate of rise .... 150F/min. & >1050F (8.30C/min. & >40,60C) <br />Low Temperature Output ,..,.........., 430F ::!:50F (6,10C ::!:2,80C) <br />Auxiliary relay contacts2A @ 28 V DC or 120 V AC (resistive) <br />Alarm contacts ..,.....,............. 500 mA @ 36 V DC (resistive) <br />Field wiring size..,............,...,......,....,..,......,...., 14 - 24 AWG <br />Packaging ,................... 10 detectors are packed in a carton <br />Color......,...............,...................,...... white cover/white base <br />with UV inhibitor to prevent yellowing <br />Listing ...........,................ UL 268, ULC FM, CSFM and MEA <br /> <br />Designator \\... DeScription ..... . <br />H Isolated Fixed Temp. Isolated fixed 1350F (570C) and rate of rise heat detector, independently trips the LED and alann <br /> and Rate of Rise Heat output, Smoke detector activates intemal sounder (local alann) and auxiliary relay, but <br /> Detector does not latch, Approved as both single station smoke alann and system heat detector, Ideal for <br /> hotel, motel and donnitory rooms where smoking is allowed. <br />R Auxiliary Relay Used to activate other devices such as elevator recall; door holders, strobes, etc. Listed for <br /> releasing service, <br />S Built-in Sounder 85dB built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. <br />SS Built-in Sounder with 85dB built-in sounder alarm when smoke is detected or when power wiring polarity is reversed, <br /> Sensitivity Status Also, chirps every 5 minutes when unit goes outside the approved sensitivity range for more <br /> Output than one day, Resetting detector will silence chirp for one day, until unit is restored to <br /> proper sensitivity, <br />T Integrated Fixed Integrated Fixed 1350F (570C) temperature and rate of rise heat detector offers double <br /> Temp, and Rate of Either heat detector or smoke detector can trip and latch LED and alann protection. <br /> Rise Heat Detector relay outputs, <br />L Low temperature Separate relay output that energizes when temperature around detector reaches 430F <br /> output ::!: 50F (6.1 oC ::!: 2,8OC) <br />E Built-in end of line Relay is nonnally energized and will trip with loss of power. Can also provide notification <br /> power supervision relay when detector needs maintenance, <br /> <br />@1999 Sentrol. Certain of the items in the Product Information Bulletin are protected under one or more of the following patents; 5,546,074; 5,708,414; <br />5,798,701; 5,821,866. <br /> <br />SENTROL <br />12345 SW Leveton Dr., Tualatin, OR 97062 <br />Tel.: 503.692.4052 Fax: 503.691.7566 <br />http://www.sentrol.com <br />U.S. & Canada: 800.547.2556 <br />Technical Service: 800.648.7424 <br />FaxBack: 1.800.483.2495 <br /> <br />ESL. <br /> <br />A PRODUCT OF SENTROL <br /> <br />Sentrol reserves the right <br />to change specifications <br />without notice. <br /> <br />@1999 Sentrol <br /> <br />E-2447-FLG15K-0996 <br />