Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br /> <br />FOR BUILDING CONSTRUCTION <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br />THE LANDINGS APARTMENTS - 1 BEDROOM Builder: .5/1AJ/)l( :i)FV. <br />THI: LANDING APARTMENTS - PH 11,:3'151'7 Permitting Office: c!.17f{ /)F zEPllf$I/us <br />ZEPHYRHILLS, FL mri9/)()wJ ,t)19/<.. t..J;4l( Permit Number: tt>9.y9 <br />TOWNVIEW MEDICAL ARTS PARTNERSHIP Jurisdiction Number: 6//60 i) <br />Central <br /> <br />I Project Name: <br />I Address: <br />City, State: <br />Owner: <br />Climate Zone: <br /> <br />1. New construction or existing <br />2. Single family or multi-family <br />3. Number of units, if multi-family <br />4. Number of Bedrooms <br />5. Is this a worst case? <br />6. Conditioned floor area (fF) <br />7. Glass area & type <br />a. Clear - single pane <br />b. Clear - double pane <br />c. Tint/other SC/SHGC - single pane <br />d. Tint/other SC/SHGC - double pane <br />8. Floor types <br />a. Slab-On-Grade Edge Insulation <br />'>. N/A <br />N/A <br />Vall types <br />'lcrete, Int Insul, Exterior <br />'e, Wood, Adjacent <br /> <br />New <br />Single family <br />1 <br />I <br />Yes <br />760fF <br /> <br />92 ,5 ft2 <br />0.0 ft2 <br />0.0 ft2 <br />0.0 ft2 <br /> <br />R=O.O, 79.0(p) ft <br /> <br />R=5.0, 632.0 ft2 <br />R=II.O, 332.0 ft2 <br /> <br />R=30.0, 760.0 ft2 <br /> <br />AH: Attic <br /> <br />Sup. R=6.0, 60.0 ft <br /> <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 23.0 kBtu/hr <br />SEER: 10.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 17.0 kBtu/hr <br />HSPF: 7.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br />a. Electric Resistance <br /> <br />Cap: 30.0 gallons <br />EF: 0.93 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HV AC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF-Whole house fan, <br />PT -Programmable Thermostat, <br />RB-Attic radiant barrier, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />PT-C, PT-H <br /> <br />'a: 0.12 <br /> <br />Total as-built points: 9365.90 <br />Total base points: 11242.00 <br /> <br />PASS <br /> <br />'pecifications covered <br /> <br />Wfh~ <br />'NEERING <br /> <br /> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br /> <br />EneravGauae@ Nersion: FLRCNA-20m <br />