<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />ADDRESS: THE LANDING APARTMENTS - PH II, ZEPHYRHILLS, FL,
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />PERMIT #:
<br />
<br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
<br />Exterior Windows & Doors 606,1 ,ABC. 1,1 Maximum:,3 cfm/sa,ft, window area; ,5 cfm/sQ,ft. door area,
<br />Exterior & Adjacent Walls 606.1,ABC,l,2,l Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & toplbottom plates; between walls and floor,
<br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> from, and is sealed to, the foundation to the top plate,
<br />Floors 606,1 ,ABC, 1 ,2,2 Penetrations/openings >lIS" sealed unless backed by truss or joint members.
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br /> to the oerimeter, oenetrations and seams,
<br />Ceilings 606,1.ABC,1,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> installed that is sealed at the oerimeter, at oenetrations and seams,
<br />Recessed Lighting Fixtures 606,1 ,ABC, 1 ,2,4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br /> conditioned space, tested.
<br />Multi-storv Houses 606.1.ABC,1,2,5 Air barrier on perimeter of floor cavity between floors,
<br />Additional Infiltration reqts 606.1 ,ABC, 1 ,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br /> have combustion air,
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES 'must be met or exceeded by all residences.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12. Switch or clear1y marked circuit
<br /> breaker (electric) or cutoff (aas) must be orovided, External or built-in heat trao reauired.
<br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools
<br /> must have a pump timer, Gas spa & pool heaters must have a minimum thermal
<br /> efficiencv of 7S%,
<br />Shower heads 612,1 Water flow must be restricted to no more than 2,5 gallons per minute at SO PSIG.
<br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically i
<br /> I
<br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. I
<br /> Ducts in unconditioned attics: R-6 min, insulation,
<br />HVAC Controls 607,1 Separate readily accessible manual or automatic thermostat for each system, I
<br />Insulation 604.1 , 602,1 Ceilings-Min, R-19, Common walls-Frame R-l1 or CBS R-3 both sides, I
<br /> Common ceiling & floors R-11,