Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: THE LANDING APARTMENTS - PH II, ZEPHYRHILLS, FL, <br /> <br />PERMIT #: <br /> <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS <br />-'~-~--~-_._,-~_.~-_._-- <br />Exterior WindQ'''''.li ~-Poo~___ <br />Exterior & Adjacent Walls <br /> <br />_:3~(;TIQ~_______ !BI:9.lJl~!:_MENTS FOR EACH PRACTICE________~___~ <br />,~~~_1.f.!!C;_=_tJ ....._.. i Maximum:,3 cfm/sq.ft. window area; .5 cfm/sq,ft. d()()r1!rea.__ <br />606,1,ABC,1,2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />i : penetrations; between wall panels & toplbottom plates; between walls and floor, <br />I ! EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> <br />-Floors ------ ---~--------+1606,1,ABC,U2j ~:~~t;;t~l:s;:~~~n~~ ;~/;~-~~~il;~~;~~~~~~I;~-truss or joint members. <br /> <br />I EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />------------ ----r----~-------i .t()the .P~irnet~l",pe_n~trationsand_sElarT1~, ___________ <br />Ceilings I 606,1,ABC.1,2.3 i Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />I I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />I I attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> <br />Re~ssed Lighting Fixtures 1606'1,ABC'1'2'4 -LI ~:~;~(\~t:d~~~~:dp:~~;~~:~~~e~;;I:~;P~;;~;:L~~so~nn:~:~~:~ed, installed inside a <br /> <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />_____.____ _____~____Ic:()nditionedspa.ce,Jested. .___. ._____ <br />Multi-story Houses 606,1,ABC,1,2.51 Air barrier on perimeter offloorcavity between floors. <br />Additional Infiltration reqts 606,1,ABC.1,3 - r E;h~u~t f~ns- v~nt~d t~ outd~~rs: d~;P~;~;comb~;tion~~ace h~aters comply with NFPA, <br />_u_ '_ . _. J h?ve cOlllbustion air. ._. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS I SECTION I REQUIREMENTS <br />Water Heate~ - 1612,1 [comPlY ";th-~ffi~i~~~yr~~~ire~~~t~-i~-T~ble-6~12, Sw~~h or clearly marked circuit <br />~~--~--i l t>rea~U~e_ctric:t()r~IJt()ffJgCll>)I11LJstJ~ElJ)rovided, External or built-in heat traD reQuired. <br />Swimming Pools & Spas 612,1 Spas & heated pOOls must have covers (except solar heated), Non-commercial pOOls <br />I must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> <br /> <br />~~-:.~::~~ :YS~~,-rl: :..11.~..'.--.-. -.--..-...-...-... - -~.t.E?~.i~~~m.i::.r::e.;!~::~;~e.I~.:.: ::.~:.n..::. d.;.:..n..lce.~.O.;. :m..i:~;.,h.:,..~"~.t~:.=:~~o -- <br /> <br />--~-~----- --- ____u___ u___ _ _ _ I ~~cts in unconditioned attics: R-6 min, insulation,__ ._ ______ _____ <br />HVAC Controls . 607 ,l_____L~paratl3..rea_djlya~cel>silJIElrn?nuClloraut()mati9 thermostat for each system. <br />Insulation 1[604,1, 602.1 i Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides, <br />i Common ceiling & floors R-11. <br /> <br />EnerovGauoe 1M DCA Form 600A-97 <br /> <br />EneravGauoe@/FlaRES'97 FLRCNA-200 <br /> <br />CHECK <br /> <br />CHECK <br />