<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: THE LANDING APARTMENTS - PH II, ZEPHYRHILLS, FL, <br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606,1 ,ABC, 1 ,1 Maximum:,3 cfm/so.ft, window area; ,5 cfm/so,ft. door area, <br />Exterior & Adjacent Walls 606,1,ABC,l.2,l Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the too alate, <br />Floors 606,1,ABC,l.2,2 Penetrationslopenings >1/8" sealed unless backed by truss or joint members, <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter, penetrations and seams, <br />Ceilings 606,1,ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the oerimeter, at aenetrations and seams, <br />Recessed Lighting Fixtures 606.1 ,ABC, 1 ,2,4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br /> conditioned saace, tested, <br />Multi-storv Houses 606,1 ,ABC, 1 ,2,5 Air barrier on aerimeter of floor cavitv between floors, <br />Additional Infiltration reqts 606.1.ABC.1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES lmust be met or exceeded bv all residences.) <br />COMPONENTS - . SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit <br /> breaker (electric) or cutoff (oas) must be Drovided, External or built-in heat traD renuired, <br />Swimming Pools & Spas 612,1 Spas & heated pOOls must have covers (except solar heated). Non-commercial poolS <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiencv of 78%, <br />Shower heads 612,1 Water flow must be restricted to no more than 2,5 oallons oer minute at 80 PSIG. <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> I attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br /> Ducts in unconditioned attics: R-6 min, insulation, <br />.HVAC Controls 607,1 Seaarate readilv accessible manual or automatic thermostat for each system. <br />Insulation I <br /> /604,1,602.1 Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides, <br /> Common ceiling & floors R-l1, <br /> <br />EneravGauoe 1M DCA Form 600A-97 <br /> <br />EnerovGauoe@/FlaRES'97 FLRCNA-200 <br />