Laserfiche WebLink
<br />FORM, 60.0A-97 <br />, ' <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: OAK RUN APARTMENTS PHASE II, ZEPHYRHILLS, FL, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE ~ , CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sa.ft. window area; .5 cfm/sa.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> , penetrations; between wall panels & toplbottom plates; between walls and floor, <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />I------~---~---~- , *--q --.- from-J.lilnd is sealed to, the fO!Jndation to thE! top plate. ~ ,~ .--. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the Derimeter, Denetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, I <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; I <br /> I <br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />___n_ _~__~I!~~lIed that.i~sealed ~the perimeter, at penetrations angJleams. ~, ~~ <br />Recessed Lighting Fixtures 606.1,ABC.1.2.4 . Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> I sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from I <br />~- .. conditioned space, tested. ,~_" . '__~_~'~'I <br />~j-story HQ.uses ~ 606.1.ABC.1,2,5 Air barrier on oerimeter of floor cavity between floors. ~'~_m. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, C <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br /> <br />COMPONENTS <br />Water Heaters <br /> <br />SECTION REQUIREMENTS CHECK <br />612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br />,~, breaker ,(electric) or cutoff (gas) must be provided. Extemal or built-in heat tra r uired. <br />612.1 Spas & heated pools must have covers (except solar heated), Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />_,_~,_~l!fficiencYQf78%._~_.~,~.,~~,~_~_~~~_, <br />612.1 . Water flow must be restricted to no more than 2.5 allons er minute at 80 PSIG. <br />I 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />I attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min, insulation, <br />607,1 mo_ I Ee !Irate readily a~ssible manual, or automatic thermostat fClr eachllystem-'___-----k_~ <br />1604.1,602.1 Ceilings-Min. R.19. Common walls-Frame R-11 or CBS R-3 both sides. I <br />Common ceiling & floors R-11. I <br /> <br />Swimming Pools & Spas <br /> <br />Shower heads <br />Air Distribution Systems <br /> <br />HV~C Contr9!~_m <br />Insulation <br /> <br />EneravGauae™ DCA Form 6OOA-97 <br /> <br />EneravGauae@!FlaRES'97 FLRCNA-200 <br />