Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: OAK RUN APARTMENTS PHASE II, ZEPHYRHILLS, FL, <br />6A-21 INFIL TRA TION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br /> -_.- <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/so.ft. window area; .5 cfm/sQ.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> ~BC122 penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> I EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />~~~_._- . .--- : from, and is sealed to, the found~t!on to the top plate. ------ -_.----- .-.-.------ <br />Floors Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> I EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> i to the oerimeter, oenetrations and seams. <br />Ceilings i 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> I soffits, chimneys, cabinets sealed to continuous air barrier; gaps In gyp board & top plate; <br /> I attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />~~._... Linstalled that is s.ealed at the perim~ter, at penetrations and seams. -_.- -- <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />~----- -- conditioned~ace, tested. -- ---. ----_.- <br />Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. I <br /> .. <br />Additionallnfiltration reqts t6.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences,) <br />~.OMPaNENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 I Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br />~~-_._--. --+ -. ._--i=Elr (electric) OLc:utoff (gas) must be provided. Extemal or built~in heat trap reauired. --- <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> i must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />.-..- -~.- efficiency elf 78%. ... --~-~- <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 callons oar minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> . attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> I Ducts in unconditioned attics: R-6 min. insulation. <br /> I <br />HVAC Contr91s -- : 607.1 t Separate readily accessible manllal or automatic thermostat for each system. .~ <br />Insulation l604.1~-.602.1 i Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> . I Common ceiling & floors R-11. <br /> ; <br /> <br />EneravGauce 1M DCA Form 600A-97 <br /> <br />EneravGauaeGWFIaRES'97 FLRCNA-200 <br />