Laserfiche WebLink
<br />01/ <br /> <br />,~~ <br /> <br /> <br />).w. SMITH ENGINEERING CO. <br /> <br />Mechanical & Architectural Enl!ineerine: <br /> <br />Phone: 352-521-0865 <br /> <br />David W. Smith, P.E. <br />9909 WaUaston Drive <br />Dade City, Florida 33525 <br /> <br />Fax: 352-521-0867 E-Mail: zeDhvr27~e:te.net <br /> <br />June 27, 2002 <br /> <br />REF. Substitution of Wood Frame wall for block wall <br />6UeeETT"E" - b-108 S/L."Ee. O,6...t~ i:)~ ~"l~U'('u <br /> <br />I hereby certify that the substitution of a 2'X6' wood frame wall (with <br />provisions as specified in the following paragraph) located at bath adjacent <br />to lanae in place of a blockwall as shown on the original plan cop lies with <br />section 1606 & all applicable sections of the Florida Building code. <br /> <br />Provisions&Specifications for said wall substitution: <br /> <br />The frame wall is to have 'l2"X6" 'J' bolts @ bottom plate located 24" a.c. <br />max, Simpson SP1&SP2 Clips or equiv at top and bottom of stud to plate <br />connections. Studs at end of walls to be fastened to block walls with 'i4"X3" <br />Tapcons. Wall to be finished with wire lathe and stucco to match. <br /> <br />David <br /> <br /> <br />~~ <br /> <br />&( & 1/b~ <br />