Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: THE LANDING APARTMENTS - PH II, ZEPHYRHILLS, FL, <br /> <br />PERMIT #: <br /> <br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENT~~~ ~TION~__~ - RE9UH:~f:"'_f:NTSF9_R~C.t1..f'f!P.C.:TJ<:;E.__~__.m___ CHECK <br />Exterior Windows & Doors 606,1,ABC,1,1 _ Maximum:_c.3_ cfm/s_gJL'Io'i_r1dow_~n~.3;.,~gr:n~g. ft, door area, <br />Exterior & Adjacent Walls 606,1,ABC,1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor, <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> . fror11.~.cLi.s_s~ale.r.L!9Lthe fou!l.clati()r1.. to ~~_e...!9j)Jllate, .. <br />Floors 606,1 ,ABC, 1 ,2,2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> I EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />~o__o_,_,_._,_~__. o__~~~ __n... ~o__~__,_ _o__ I to the perimeter, penetrations and seams'm_____ ________ <br />Ceilings 606,1,ABC,1,2,3 I Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> I attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> --'-~ ~nst,!lIed t!1C1t.is seal~dil!.tb~p~!ir11.e~!J...CI!J>enetrations and seams, <br />Recessed Lighting Fixtures 606,1 ,ABC.1 ,2,4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> I sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditione_(U)paCEl.,!~~!~_c:l.___ ___'o______'u______. _________ <br />Multi-story Houses 606.1,ABC,1,2c.!L_ Air bCl.~r~()n perirne.t~~ otfl'p()r (;~vitYI:>~tv.leen floors, <br />Additional Infiltration reqts 606,1,ABC.1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. _-on <br /> 0.' _ "'.._ ,.__.., .____, .. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION _~.gUlREr.1.f:NTS --"- ------ --- ---- ---_._---._~---,---- CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit <br /> break~(elef!ric) or_~lJtof!.(g~}_r:nU!)tl:>.~.Jl.rovided: External or built-in heat trao reauired. <br />Swimming Pools & Spas 612,1 Spas & heated pOOls must have covers (except solar heated), Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> __ efficiency ofL8%,_________.._ "- -..--- ---------",-,- <br />Shower heads 612,1 Water flow rTl_usttJe_rEl~.tr1ged to nQ.rTl..or~than 2,5 aallons oer minute at 80 PSIG. <br />Air Distribution Systems 1610., All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />I attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br /> Ducts in unconditi(>.~~._~t!L~:J3::{) rTl!fl.i!!.5.ulCl.!L()!l_, <br />HVAC Controls 1607,1 Separate readili'~ccessibl~_-,,!!~.n\!Cl1 or automatic thermostat for each system. <br />Insulation 1604,1,602,1 I Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides, <br /> I <br /> I Common ceiling & floors R-11, I <br /> <br />EneravGauae TM DCA Form 600A-97 <br /> <br />EneravGauae<ID/FlaRES'97 FLRCNA-200 <br />