Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details. <br /> <br />ADDRESS: THE LANDING APARTMENTS - PH II. ZEPHYRHILLS, FL. <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENIL_____._ SECTION .13~g\JIB~MEN!S_f()~I:ACI-I_I'~C:rI~_E __._~______ CHECK <br />-----------~- ----- <br />Exterior Windows & Doors 606.1.ABC.1.1 --- .1\,1~!Il1.~_rTl: ..3. c:fl11/S..9JLwil'ldo'!VarEl13;:s.~frJ)/sq.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is.se'!led to,Jhe fO~!1dation to the top plate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />I-~-------~------ -~-~.- !()JI1~J)l'lr!.metElr, .P~flEl.!@tig n.s _a n.Q._~e~.rTl~'.__ <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that~~ealed atthEl_Q.EWmet~enetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, Installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> . conditiClrle(:LsR9.~Lte~ted_. --~_._---~. <br />Multi-story Houses 606. '.ABC. i'i~ ba";"o"_peom.",offio", ,"vUy b......" floo",.. _ __ _._ <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fansvented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have coml:l!lstion air. ._ . ._. . <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS -- ~CTION REQI,!IRE-""II:~T~___ _u__. _u___. ..___~__~__~____~~_. CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker (!llectric) or cutoff {g~ll1.u~!>5!J)rovided. External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> effiCiency oE~'&_ __._______ ------- --~--._-- <br />Shower heads 612.1 Water flow must be restrict<<;,d to no more than 2.5 Qallons per minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> ---i attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> D~s in unconditioned attics: _R-tl..rnin. insulation. <br />HVAC Controls 607.1 ~~"te_""jIY ,--"".';b,"-_m""_"'.9,-,-"o_"",b' ".""a,tat (0, .,... ,..!em. <br />Insulation 1604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EneravGauae™ DCA Form 600A-97 <br /> <br />EneravGauae@/FlaRES'97 FLRCNA-200 <br />