Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: THE LANDING APARTMENTS - PH II, ZEPHYRHILLS, FL, <br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENT~ EQR EACI!P~0~E:___ CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfn:!/~JL\foIiI1Qow area~,-5 cfm/sq.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> I EXCEPTION, FMme wa'. wheM a ""Ii"",", 'mi'baI'o, barrie, i, '",ta"od thai extaM, <br />-- Jrol11, ancjls ~eal~<!!(), t~-.lqlJl1~Cltig_n-1o -1he top plate. <br />Floors 606.1.ABC.1.2.2 , Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to th~erimeter,--Rene!rati~'l!'~~~~!!!~.___ <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> instal~I:lJl:l~'-i~_~~~cjjil.tI1_El.[lE~!tm~te!,--a~ [lenetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> I sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> ~1r'dlIi0J'eJ!"~"'J"''''' ---~-~ - ---~- ~ <br />Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> --... - - .. -". ---- ',... --- ...- .- - <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION _ ~REgyIJ~~_~t:!4J:s. .-_._-_.._----_._-~--- - - ~- .----- CHECK <br /> --_'0_-..._- <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker ~ctricLQr cU!Q!L(g~~).1!1J!st be provided. External or built-in heat trap reQuired. <br />Swimming Pools & Spas 612.1 Spas & heated pOOls must have covers (except solar heated). Non-commercial pOOls <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> f---------__ ~!!icienc;}'Qf.?8~c_ --.---------- <br />Shower heads 612.1 WClt~~!'_o'JV..!T1_lI~tb~~r~stric:te<:l_'o_n()ll1or_~_'h~~~.i>_gallons per minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607.1 ~~.2..ar:a!~_r~~<:lil~ac:c:.El~slblern_anuaU~~ alJt()ll1Cl!ic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnerovGauoe TM DCA Form 600A-97 <br /> <br />EnerovGauoe<ID/FlaRES'97 FLRCNA-200 <br />