Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: THE LANDING APARTMENTS - PH II, ZEPHYRHILLS, FL, <br /> <br />PERMIT #: <br /> <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION --- _~EQU.!~E:~_El"'-T~9'3 EA9ti_~_~~TIC_E ._._--_.._--_...._.._---~-- CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Ma:qmum:..;3c;frTl~:ft."__'lVin<!<>.~a!ea;~..clrrJ~g.1t. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 I Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> ! foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is seale<!..tg2_!D_e.19I,JDciatLOrlJo thE!.!O.p_~te. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> I EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />Ceilings 606.1.ABC.1.2.3 r~e~;;~~~:e~:~~~~~i~;~~~~~ti~~::;~iiing plane of top floor; around shafts, chases, <br /> I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />-- o Jr!.!)tallecjth<lti~~e.ClIE!d ..atthe~e.ril'Tleter-,.<l!.~etrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations. sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned~~ce,__~ste_d,---______________ <br />Multi-storv Houses 606.1.ABC.1.2.5 _ Air barri~()rlJ)~irrJ.Elte!_of~()gr(:c~yitY_I:l~een fIOQ~_ <br />Additionsllnfiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> --.. have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION -~ RE:9U1REI\III:r.iI.5 -- -- - ---------..- CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> L!>!eilker_(elE!ctricJ()r_ClJtOffjgClsLl'Tlu~tb.ElJ)fovided. External or built-in heat trae reauired. <br />Swimming Pools & Spas 612.1 I Spas & heated pOOls must have covers (except solar heated). Non-commercial pools <br />Shower heads __~_ _~~__~l;;i~~::Q;::~.Pt,:e~~~as:p: & P=Ih::te~must have a m.inimum thermal <br /> 612.1 I Wa!El.r_~()I.',f_rTlu~LbE!..!.estricted .1.0_-"0 mQr:~.!tl.<l_n 2.5 gallons per minute at 80 PSIG. <br />Air Distribution Systems ,610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> i I attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> I Duct!)Jr:u,!rlconclil.i.c>_ned atti~R-1l/'llin.,ll]~ulation. <br />HVAC Controls 607.1 Separ~~r.~_a<!iIY~l:~~slt:>.~_rrJaDlJalpr.a_utomatic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EneravGauae TM DCA Form 600A-97 <br /> <br />EneravGauaOO>/FlaRES'97 FLRCNA-200 <br />