<br />. FORM 600A-2001 <br /> <br />Code Compliance Checklist <br />. Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: · · · <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior WindoWs & Doors 606.1.ABC.1.1 Maxlmum:.3 cfmlsa.ft. windOw area' .5 cfm/sa.ft. door area. <br />Exterior & Aaj8Cent WaDs 606.1 .ABC.1.2.1 Caulk, gasket, wreathersttip or seal between: windows/doors & frames, surrounding watl; <br /> foundation & waD sole or sill plate; joints between exterior waR panels at corners; utility <br /> penetrations; between wan panets & topJbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous Infiltration barrier Is instaRed that extends <br /> from and Is sealed to the foundation to the too Dlate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame fIoor$ where a continuous Infiltration barrier Is installed that Is sealed <br /> to the oerimeter and seams. <br />Ceilings 606.1.ABC.1.2.3 Between watls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cab/nets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that Is sealed at the oerimeter at and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, Installed inside a <br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned &DaCe. tested. <br />Multt-storv Houses 606.1.ABC.1.2.5 Air barrier on of floor cavitY between floors. <br />Additionallnflttration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combUstion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences.} <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WatN Heaters 612.1 Comply with effICiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker (electric) or cutoff (aas) must be Drovlded. External or built-in heat traD reaulred. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> effIciencv of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 aatlons IlN minute at 80 PSIG. <br />Air Distribution Systems 610.1 An ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, Insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607.1 Seoarate readilY accessible manual or automatic thermostat for each svstem. <br />Insulation 604.1, 602.1 Ceilings..Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiHng & floors R-11. <br /> <br />EnergyGauge.... DCA Form 6OOA-2001 <br /> <br />EnergyGa~FIaRES'2001 FLRCPB v3.21 <br />