My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
02-1401
Zephyrhills
>
Building Department
>
Permits
>
2002
>
02-1401
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:54:40 PM
Creation date
11/16/2006 8:17:45 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
02-1401
Building Department - Name
RYMAN CONST
Address
37527 LAUREL HAMMOCK DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Residential System Sizing Calculation <br />Summary <br />Project Title: <br />Borders Residence <br /> <br />Code Only <br />Profe~onalVersion <br />Climate: Central <br /> <br />7/18/02 <br /> <br />Location for weather data: Oriando - Defaults: Latitude(28) Temp Range(M) <br />Humidit data: Interior RH 50% Outdoor wet bulb 6 Humidit difference r. <br />Winter design temperature 38 F Summer design temperature <br />Winter setpoint 70 F Summer setpoint <br />Winter tem rature difference 32 F Summer tem rature difference <br />Total heatin load calculation 17718 Btuh Total coolin load calculation <br />Submitted heating capacity 48000 Btuh Submitted cooling capacity <br />Submitted as % of calculated 270.9 % Submitted as % of calculated <br /> <br />93 F <br />75 F <br />18 F <br />23698 Btuh <br />48000 Btuh <br />202.6 % <br /> <br />WINTER CALCULATIONS <br />ft <br /> <br />Winter Heatin Load for 2022 <br />Load com nent <br />Window total <br />Wall total <br />Door total <br />Ceiling total <br />Floor total <br />Infiltration <br />Subtotal <br />Duct loss <br />TOTAL HEAT LOSS <br /> <br />sqft <br />sqft <br />sqft <br />sqft <br />sqft <br />cfm <br /> <br />230 <br />1422 <br />21 <br />2022 <br />158 <br />135 <br /> <br />Load <br />5330 <br />3697 <br />316 <br />2224 <br />553 <br />4754 <br />16875 <br />844 <br />17718 <br /> <br />Btuh <br />Btuh <br />Btuh <br />Btuh <br />Btuh <br />Btuh <br />Btuh <br />Btuh <br />Btuh <br /> <br /> <br />W.II9Ql%) <br /> <br />SUMMER CALCULATIONS <br />ft <br /> <br />Summer Coolln Load for 2022 <br />Load com nent <br />Window total <br />Wall total <br />Door total <br />Ceiling total <br />Floor total <br />Infiltration <br />Intemal gain <br />Subtotal(sensible) <br />Duct gain <br />Total sensible gain <br />Latent gain(infiltratlon) <br />Latent gain(intemal) <br />Total latent gain <br />TOTAL HEAT GAIN <br /> <br />sqft <br />sqft <br />sqft <br />sqft <br /> <br />230 <br />1422 <br />21 <br />2022 <br /> <br />118 cfm <br /> <br />Load <br />5157 Btuh <br />2474 Btuh <br />213 Btuh <br />2871 Btuh <br />o Btuh <br />2340 Btuh <br />3600 Btuh <br />16656 Btuh <br />1666 Btuh <br />18322 Btuh <br />3536 Btuh <br />1840 Btuh EnergyGauge<!l~ sysj ~~Ing~ on AC.9~nual J. <br />5376 Btuh PREPARED BY:~/ - <br />23698 Btuh DATE: 7- I -0.;1. <br />EnergyGauge@ FLRCPB v3.21 <br /> <br /> <br />Ceiling$(12%> <br /> <br />InlH.(1o%) <br />
The URL can be used to link to this page
Your browser does not support the video tag.