Laserfiche WebLink
<br />SECTION 3 <br /> <br />1/4" x 6" RAWL TAPPER <br />THROUGH 1" x 2" AND ROW <br />LOCK INTO FIRST COURSE OF <br />BRICKS <br /> <br />ALTERNATE CONNECTION OF <br />SCREENED ENCLOSURE FOR <br />BRICK OR OTHER NON- <br />STRUCTURAL KNEE WALL <br />1" WIDE x 0.063" THICK STRAP <br />@ EACH POST FROM POST TO <br />FOOTING WI (2) #10 x 3/4" <br />S.M.S. STRAP TO POST AND <br />(1) 1/4" x 1.314" TAPCON TO <br />SLAB OR FOOTING <br /> <br />SCREEN, VINYL, GLASS & MODULAR ROOMS <br /> <br /> <br />ALUMINUM FRAME SCREEN <br />WALL <br />ROW LOCK <br />BRICK KNEEWALL TYPE S <br />MORTAR REQUIRED FOR <br />LOAD BEARING BRICK WALL <br />4" (NOMINAL) PATIO <br />CONCRETE SLAB W/6 x 6 . <br />10 x 10 WELDED WIRE MESH <br />OR FIBER MESH CONCRETE <br /> <br />.~ - ---~. <br />41 . <br /> <br />(1) #5 l(J BARS WI 3" COVER <br />(TYPICAL) <br /> <br />. . <br />. <br /> <br />. <br /> <br />BRICK KNEE WALL AND FOUNDATION FOR SCREEN WALLS <br />SCALE: 314" = 1'..()" <br /> <br />12" <br />TYPE I TYPE II TYPE III <br />FLAT SLOPE I NO FOOTING MODERATE SLOPE FOOTING STEEP SLOPE FOOTING <br />NOTES: 0-2./12" 2"/12". 1'-10" > 1'.10" <br /> <br />1. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1,500 PSF. <br />BEARING CAPACITY OF SOIL SHALl BE VERIFIED, PRIOR TO PLACING THE SLAB, BY FIELD SOIL <br />TEST OR A SOIL TESTING LAB. <br />2. THE SLABlFOUNDATlON SHALL BE CLEARED OF DEBRIS, ROOTS, AND COMPACTED PRIOR TO <br />PLACEMENT OF CONCRETE. <br />3. NO FOOTING REQUIRED EXCEPT WHEN ADDRESSING EROSION UNTIL THE PROJECTION FROM <br />THE HOST STRUCTURE EXCEEDS 16' THEN A TYPE II FOOTING IS REQUIRED. SLABS SHALL BE A <br />MINIMUM OF 3-112" (4" NOMINAL) THICK. <br />4. MONOLITHIC SLABS AND FOOTINGS SHALL BE MINIMUM 2,500 PSI CONCRETE WITH 6 x 6.10 x 10 <br />WELDED WIRE MESH OR FIBER MESH MAY BE USED IN LIEU OF MESH. <br />5. IF LOCAL BUILDING CODES REQUIRE A MINIMUM FOOTING USE TYPE II FOOTING OR FOOTING <br />SECTIONS REQUIRED BY LOCAL CODE, LOCAL CODE GOVERNS. <br />(SEE ADDITIONAL DETAIL FOR STRUCTURES LOCATED IN ORANGE COUNTY, FL) <br />6. IF A CARRIER BEAM OR FORTH WALl FRAME IS REQUIRED USE A TYPE II FOOTING MINIMUM. <br /> <br />2'..(). MIN. <br />r BEFORE SLOPE I <br /> <br />1~JS[SISISI <br /> <br /> <br /> <br />3-112" (TYP. (1) #5 BAR CONT. <br />ALLSLABS) I. __- <br />~ ~... <br />. <br /> <br /> <br />J <br /> <br /> <br />SLAB-FOOTING DEl AILS <br />SCALE: 3/4" = 1'.0. <br /> <br />Lawrence E. Bennett, P.E. <br />CML ENGINEER. DEVaOPMENT CONSUL TANT <br />P.O. BOX 4368. SOUTH DAYTONA, FL 32121 <br />TELEPHONE (3861767~n.. <br />FAX (3861767~ <br /> <br />SEAL <br />PAGE <br /> <br />) <br />--'" <br /> <br />3-22 <br /> <br />@ COPYRIGHT 2002 <br />NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOllT THE WRIlTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. <br />