Laserfiche WebLink
<br />FORM 600A-2001 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: , , , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmlso.ft. window area' .S cfmlso.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & topJbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and Is sealed to the foundation to the too olate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/ff' sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is Installed that is sealed <br /> to the oetimeter oenetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceitings where a continuous Infiltration barrier is <br /> installed that is sealed at the oetimeter at oenetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/Z' clearance & 3" from insulation;. or Type IC rated with < 2.0 cfm from <br /> conditioned saace tested. <br />Multi-storv Houses 606.1.ABC.1.2.S Air barrier on oetimeter of floor cavitY between floors. <br />Additional Infiltration reqts 606.1 .ABC .1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bvall residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. SY.Iltch or clearly marked circuit <br /> breaker (electric) or cutoff (na....\ must be orovided. External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). No~mmercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efflciencv of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.S aallons oer minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the crtterla of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each sYStem. <br />Insulation 604.1 , 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGaugeâ„¢ DCA Form 6OOA-2001 <br /> <br />EnergyGauge@/FlaRES'2001 FLRCPB v3.21 <br />