Laserfiche WebLink
<br />System Sizing Calculations - Winter <br />Residential Load - Component Details <br />Project Title: <br />Model 1845 <br /> <br />Code Only <br />Professional Version <br />Climate: Central <br /> <br />Reference City: Orlando (Defaults) Winter Temperature Difference: 32.0 F <br /> <br />8/27/02 <br /> <br />Window Panes/SHGClFrame/U Orientation Area X HTM= Load <br />1 1, Tint, Metal, DEF N 32.4 37.0 1198 Btuh <br />2 1, Tint, Metal, 1.00 N 7.1 32.0 226 Btuh <br />3 1, Tint, Metal, 1.00 E 32.0 32.0 1024 Btuh <br />4 1, Tint, Metal, 1.00 W 32.4 32.0 1036 Btuh <br />5 1, Tint, Metal, 1.00 W 23.2 32.0 744 Btuh <br />6 1, Tint, Metal, 1.00 W 36.0 32.0 1152 Btuh <br /> Window Total 163 5380 Btuh <br />Walls Type R-Value Area X HTM= Load <br />1 Frame - Exterior 13.0 1456 2.6 3786 Btuh <br /> Wall Total 1456 3786 Btuh <br />Doors Type Area X HTM= Load <br />1 Wood - Exter 21 14.7 309 Btuh <br /> Door Total 21 309Btuh <br />Ceilings Type R-Value Area X HTM= Load <br />1 Under Attic 30.0 1845 1.1 2030 Btuh <br /> Ceilina Total 1845 2030Btuh <br />Floors Type R-Value Size X HTM= Load <br />1 Slab-On-Grade Edge Insul 0 182.0 ft(p) 25.9 4714 Btuh <br /> Floor Total 182 4714 Btuh <br />Infiltration Type ACHX Building Volume CFM= Load <br /> Natural 0.40 13780(sqft) 92 3240 Btuh <br /> Mechanical 0 o Btuh <br /> I Infiltration Total 92 3240 Btuh <br /> <br /> Subtotal 19458 Btuh <br />Totals for Heating Duct Loss(using duct multiplier of O.OS} 973 Btuh <br /> Total Btuh Loss 20431 Btuh <br /> <br />Key: Window types (SHGC - Shading coeffICient of glass as SHGC numerical value or as clear or tint) <br />(Frame types - metal, wood or insulated metal) <br />(U - Window U-Factor or 'DEF' for default) <br />(HTM - ManualJ Heat Transfer Multiplier) <br />Key: Floor size (perimeter(p) for slab-on-grade or area for all other floor types ) <br /> <br />EnergyGauge@ FLRCPB v3.21 <br />