Laserfiche WebLink
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />CHAPTER 4 - Commercial Building Compliance Methods <br /> <br />FORM 400D-01 <br />Renovations & Systems Prescriptive Method <br /> <br />ALL CLIMATE ZONES <br /> <br /> <br />ZEPHYRHILLS <br /> <br />Zone: 4 <br />Building Classification: <br />Building Permit No.: <br />Permitting Office: <br />Jurisdiction No_: <br /> <br />Ze h rhills <br />611600 <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE IU AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete ICBS N A Under Attic T 1If I A Slab-on-orade KfT7S: Wood N I A S,nnle, wa!l NTi1 <br />Wood frame Sinole Assemb;v I Raised Wood Metal Double. wall <br />Metal frame Other: I Raised Concrete Insulated Sinnle. roof <br />Insulation R-value InSulation R.vaJue I Insulation R-va]ue Other I Double_ roof <br /> <br /> SYSTEMS INFORMATION <br /> AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUtH TYPE <br />Unitary & Heat Pump Central & Heat Pump Electric <br /><65.000 Btu/h _SEER li/-A <65,000 Btuth _ HSPF N/-A- Resistance ~ <br />~65.000 Btu/h _EER _IPLV - 2:65_000 Btu/h _COP - Dedicated Heat Pump 0 <br />Water cooled _EER _IPLV - Water cooled _COP - Gas <br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0 <br />PTAC _EER - Electric Resistance _COP - LPG 0 <br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0 <br />Gas heat pump _COP - <225_0001300_000 Btulh _ AFUE - Other: 0 <br />Other: - - - ~225.0001300,000 Btu!h _E, - <br />LIGHTING Total Lighting Wattage 116990 1.59 I SIZING CALCULATION I DUCTS R-value b <br /> = (II required) ~ Location Cond. S1 <br />Total Conditioned Flocr Area 73467 Watts!sq.ft A !tach ed <br /> <br />ace <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />Components Section I Requirements I Check <br />Operations Manual 102_1 i Operations manual will be orovided to owner_ 1\: <br />Windows 406.1 I MaXimum of _3 cfm per sq.ft of window area. V <br />Doors 406.1 ! Maximum cf 1.2 cfm per sq.ft. of door area X <br />JointsiCraCKs 406_1 ! To be caulked, gasketed. weatherstripped or otherwise sea!ed. V <br />Reheat 407_1 I Electric resistance reheat prohibited X <br />Ventilation I 409.1 I Supplied with read;jy accessibie switch for shut.off and/or volume reduction when ventilation is not required. v <br />HVAC Efficiency 4071.408.1 I Minimum efficiencies - Heating: Tables 4-7.4-8_ 4-9. Cooling: Tables 4-3_ 4-4, 4-5, 4-6. X <br />HVAC Controls 407.1 Separate readily acceSSible manual or automatic thermostat for each system_ v <br />HVAC Ducts 410.1 I Air dCicts_ fittings. mechanical equipment and plenum chambers shall be mechanically attached, sea~ed. insulated <br /> I and installed in accordance with the critena of section 410.1 X <br />Balancing 410.1 I HVAC distribution system(sl tested and balanced X <br /> i <br />Piping InsuJaLon 411.1 I I n accordance w!th Table 4.11. r;:- <br />\/Vater Heaters 412.1 I Automatic e!ectnc storage water heaters $120 gallons and gas & oil fired storage water heaters ,5;75.000 Btuih shall meet <br /> i performance requirements in Table 4-12 Elec1nc >120 ga!lons: standby loss <;_30+27N,. Gas >75.0CO. Oil >105.000: E. .78, X <br /> i Standby loss <; 1.30+114/V,. Gas. Oil > 155,000. E78_ Standby loss ~ 1.30+95N, <br />Swimming Pools 4121 ! Spas & heated pools must have cevers. Non.commerc:al pools must have pump t;mer. Gas spa!!. pool heaters must N/A <br />& Spas j have a minimum thermal efficiency of 78(}!o <br />Hot Water Pipe 4121 i Plp,ng heat loss is limited to the leve's.n Table 4-11 for Circulating systems and the first 8- of pipe from a storage <br />Insulation , tank X <br />I,-Vater Fixtures 412.1 I Shower head water fiow restncted to maXimun1 of 25 gpm at 80 psi. Toilets meet 42CFR 6295(kl. PUbiic lavatory fixture I <br /> I rnax:num flow of .5 gprn; or !f self-eiasing v':iive. .25 gallon c:reu!~Hing, .5 gal!on non.c:rcu1ating X <br />Ught. ng "1415.1 Bafi':'1sls ~,:)ajl have Power Factors no Jess than .90 I X <br />-- <br /> <br />If required by ~iorica ~3'N. I hereby certfy tr;;l tr,b S'istem design is in compii8>iCe w;tr, the F!orida Energy Code. Registration No <br />ARCHITECT PET~.~__.J. Hl;SC;UTT u . 0014928LFL <br />E LECTRI CA ,_ S'~S~~-M DES IG.~~~. ___BRyii{__~_~==iAr=~::=.E~=E=~==========================================.?!~=EtJlE~=================== <br />L I G HTIN G SYSTEM DESIGN ER _____BRYAtLP_~__ZAE.F_..-J>-LE...-_______ -------------______________________4.6.1_4J_Lf1__________________ <br />MEC HAN ICA,- SYSTEM DESIGNER. .. ... G ERARD ..._L~.ABRAMS. ... ..P..E.____ _ _ ...... .._ .__ _.___.. __________ m___.. 4.2 7.8_6.lF.L__._____ _ __.. ...__. <br />PLurvlBINGSYSTEMDESIG~IERn___GERARD__L.~ ABRAMS. _P~E. __ _ _ _ _ _ _ _ 4_Z78f?}FL _ ___ _ _ <br /> <br />OWNER AGENT: _..______...___._._..__.......... _............_______nn <br /> <br />DATE' <br /> <br /> <br />DATE: <br /> <br />~~~~l.)b~~~rti~:i that~:> thE; PIa." iJ.' rd sner:2.if.i.ca::..... s. ./"7.0 C'.:.'; /"O:;!.j b~.' :h~)..o.aICU!?!i~r~ are in c.cmp'i." !~ce W.itl~... th." <br />r.c"cc"'lt::....rgJ Cod... ~ <br /> <br />PREPARED BY: . DATE: '7- 6 - O-Z- <br />I hl';r~)by certify th;t-'ih-;s t;~Ti~ji;g.-:~.i~-c~-~~i-;,T,~.~.~.; ~,":iih-(h'~" ~i;~ic~ ~E;~~gy-C~de .--..-. __...._.u. - -- --- <br />