<br />CENTRAL A 2-01
<br />
<br />Model A 11
<br />~ & 8.Q K-factor
<br />Standard Response
<br />Standard Coverage
<br />
<br />Upright & Pendent Pendent Fusible Solder Type Automatic Sprinkler
<br />
<br />Tyco Fire Products --- www.centralsprinkler.com
<br />451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA
<br />Customer Service/Sales: Tel: (215) 362-0700 I Fax: (215) 362-5385
<br />Technical Services: Tel: (800) 381-9312 1 Fax: (800) 791-5500
<br />
<br />~ General
<br />U Description
<br />
<br />-_/
<br />
<br />The Central Model A Upright & Pendent
<br />Automatic Sprinklers are standard
<br />response - standard coverage, fusible
<br />solder type spray sprinklers designed for
<br />use in light, ordinary, or extra hazard,
<br />commercial occupancies such as banks,
<br />hotels, shopping malls, factories, refiner-
<br />ies, chemical plants, etc.
<br />These sprinklers are available with wax
<br />and lead coatings that may be utilized to
<br />extend the life of copper alloy sprinklers
<br />beyond that which would othenNise be
<br />obtained when exposed to corrosive
<br />atmospheres.
<br />Although wax and lead coated sprinklers
<br />have passed the standard corrosion tests
<br />of the applicable approval agencies, the
<br />testing is not representative of all possible
<br />corrosive atmospheres. Consequently, it is
<br />recommended that the end user be
<br />consulted with respect to the suitability of
<br />these corrosion resistant coatings for any
<br />given corrosive environment. The effects
<br />of ambient temperature, concentration of
<br />chemicals, and gas/chemical velocity,
<br />should be considered, as a minimum,
<br />along with the corrosive nature of the
<br />chemical to which the sprinklers will be
<br />exposed.
<br />Operation: A fusible alloy is sealed into a
<br />bronze actuating rod (center strut) by a
<br />stainless steel ball. When the alloy melts
<br />at its rated temperature, the ball is forced
<br />upward into the center strut, releasing the
<br />!\vo ejectors and operating the sprinkler.
<br />WARNING
<br />
<br />The Model A Upright & Pendent Sprin-
<br />klers described herein must be installed
<br />and maintained in compliance with this
<br />document, as well as with the applicable
<br />standards of the National Fire Protection
<br />Association, in addition to the standards of
<br />any other authorities having jurisdiction
<br />Failure to do so may impair the integrity of
<br />these devices.
<br />
<br />The owner is responsible for maintaining
<br />their fire protection system and devices in
<br />proper operating condition The installing
<br />
<br />contractor or sprinkler manufacturer
<br />should be contacted relative to any
<br />questions.
<br />
<br />~ Technical
<br />ilIII Data
<br />
<br />Sprinkler Identification Number
<br />SIN C1211 - A Pend (K=2.8)
<br />SIN C1111 - A UP (K=2.8)
<br />SIN C2211 - A Pend (K=4.2)
<br />SIN C2111 - A UP (K=4.2)
<br />SIN C3211 - A Pend (K=S.6)*
<br />SIN C3111 - A UP (K=S.6)*
<br />SIN C4211 - A Pend (K=8.0)*
<br />SIN C4111 - A UP (K=M)*
<br />SIN C4911 - A Pend (K=8.0, 1/2" NPT)*
<br />SIN C4811 - A UP (K=8.0, 1/2" NPT)*
<br />
<br />Approvals
<br />UL & ULC Listed. FM, LPC, VDS,
<br />NYC Approved
<br />(Refer to Table 1 - 4. The approvals
<br />apply only to the service conditions
<br />indicated in the Design Criteria Section)
<br />
<br />Maximum Working Pressure
<br />175 psi (12,1 bar)
<br />250 psi (17,3 bar) UL & ULC (K=S.6)
<br />
<br />Pipe Thread Connection
<br />1/2 inch NPT -(K=2.7, 4.2, 5.6 & 8.0)
<br />3/4 inch NPT - (K=8.0)
<br />
<br />Discharge Coefficient
<br />K = 2.8 GPM/psi'l2 (40,3 LPM/bar'l2)
<br />K = 42 GPM/psi'12 (60,5 LPM/bart12)
<br />K = 5.6 GPM/psi'J2 (80,6 LPM/barl12)
<br />K = 8.0 GPM/psi'l2 (116,8 LPM/bar'l2)
<br />
<br />Temperature Ratings
<br />16S'FI740C, 2120F/100oC, 2860F/1410C
<br />
<br />Finishes
<br />Sprinkler: White Polyester, Chrome
<br />Plated, or Natural Brass
<br />
<br />Corrosion Resistant Coatings
<br />Sprinkler. Wax, Lead & Wax-over-Lead
<br />
<br />* Head Guard & Water Shield:
<br />G-2 (Guard) - (K=S.6 & K=8.0) Up & Pend.
<br />WSG-2 (Guard & Shield) - (K=8.0) Up
<br />WS-2 (Shield) - (K=S.6) Pendent
<br />Factory Assembled Model A Pendent and
<br />Model A MIL Shield. (K=S.6 & K=8.0)
<br />
<br />(See Data Sheet 3-12.0 for details)
<br />
<br />~
<br />
<br />
<br />[EI\ITRAL
<br />
<br />..; ........
<br />
<br />".......
<br />
<br />I.' , '\.i~_:~"
<br />
<br />f::
<br />
<br />
<br />;~
<br />
<br />s,_
<br />
<br />v~~
<br />~~
<br />. . ,~
<br />~J#
<br />-S=='c~
<br />~
<br />
<br />III
<br />. -r;1' --._..".'...:~ ,
<br />. .- _..c.:...
<br />
<br />~~, .t,
<br />~. '. . ..,.,:;:.....
<br />..::~, ;'f';;'"
<br />!'" ;-:---:..
<br />- .-.
<br />~.- - . . ,'~.:o .
<br />.........
<br />
<br />-,...";~._/'.\-.
<br />:..~.~:..
<br />
<br />Standard Spray
<br />Upright &
<br />Pendent
<br />Sprinklers
<br />
<br />Physical Characteristics
<br />The Model A Upright & Pendent Sprin-
<br />klers utilize a dezincification resistant
<br />(DZR) bronze frame and a brass deflector.
<br />The waterway is sealed with copper seal
<br />disk, and the fusible assembly is con-
<br />structed of bronze and stainless steel
<br />components.
<br />
<br />No. 1-1.0
<br />
|