Laserfiche WebLink
<br />CENTRAL A 2-01 <br /> <br />Model A 11 <br />~ & 8.Q K-factor <br />Standard Response <br />Standard Coverage <br /> <br />Upright & Pendent Pendent Fusible Solder Type Automatic Sprinkler <br /> <br />Tyco Fire Products --- www.centralsprinkler.com <br />451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA <br />Customer Service/Sales: Tel: (215) 362-0700 I Fax: (215) 362-5385 <br />Technical Services: Tel: (800) 381-9312 1 Fax: (800) 791-5500 <br /> <br />~ General <br />U Description <br /> <br />-_/ <br /> <br />The Central Model A Upright & Pendent <br />Automatic Sprinklers are standard <br />response - standard coverage, fusible <br />solder type spray sprinklers designed for <br />use in light, ordinary, or extra hazard, <br />commercial occupancies such as banks, <br />hotels, shopping malls, factories, refiner- <br />ies, chemical plants, etc. <br />These sprinklers are available with wax <br />and lead coatings that may be utilized to <br />extend the life of copper alloy sprinklers <br />beyond that which would othenNise be <br />obtained when exposed to corrosive <br />atmospheres. <br />Although wax and lead coated sprinklers <br />have passed the standard corrosion tests <br />of the applicable approval agencies, the <br />testing is not representative of all possible <br />corrosive atmospheres. Consequently, it is <br />recommended that the end user be <br />consulted with respect to the suitability of <br />these corrosion resistant coatings for any <br />given corrosive environment. The effects <br />of ambient temperature, concentration of <br />chemicals, and gas/chemical velocity, <br />should be considered, as a minimum, <br />along with the corrosive nature of the <br />chemical to which the sprinklers will be <br />exposed. <br />Operation: A fusible alloy is sealed into a <br />bronze actuating rod (center strut) by a <br />stainless steel ball. When the alloy melts <br />at its rated temperature, the ball is forced <br />upward into the center strut, releasing the <br />!\vo ejectors and operating the sprinkler. <br />WARNING <br /> <br />The Model A Upright & Pendent Sprin- <br />klers described herein must be installed <br />and maintained in compliance with this <br />document, as well as with the applicable <br />standards of the National Fire Protection <br />Association, in addition to the standards of <br />any other authorities having jurisdiction <br />Failure to do so may impair the integrity of <br />these devices. <br /> <br />The owner is responsible for maintaining <br />their fire protection system and devices in <br />proper operating condition The installing <br /> <br />contractor or sprinkler manufacturer <br />should be contacted relative to any <br />questions. <br /> <br />~ Technical <br />ilIII Data <br /> <br />Sprinkler Identification Number <br />SIN C1211 - A Pend (K=2.8) <br />SIN C1111 - A UP (K=2.8) <br />SIN C2211 - A Pend (K=4.2) <br />SIN C2111 - A UP (K=4.2) <br />SIN C3211 - A Pend (K=S.6)* <br />SIN C3111 - A UP (K=S.6)* <br />SIN C4211 - A Pend (K=8.0)* <br />SIN C4111 - A UP (K=M)* <br />SIN C4911 - A Pend (K=8.0, 1/2" NPT)* <br />SIN C4811 - A UP (K=8.0, 1/2" NPT)* <br /> <br />Approvals <br />UL & ULC Listed. FM, LPC, VDS, <br />NYC Approved <br />(Refer to Table 1 - 4. The approvals <br />apply only to the service conditions <br />indicated in the Design Criteria Section) <br /> <br />Maximum Working Pressure <br />175 psi (12,1 bar) <br />250 psi (17,3 bar) UL & ULC (K=S.6) <br /> <br />Pipe Thread Connection <br />1/2 inch NPT -(K=2.7, 4.2, 5.6 & 8.0) <br />3/4 inch NPT - (K=8.0) <br /> <br />Discharge Coefficient <br />K = 2.8 GPM/psi'l2 (40,3 LPM/bar'l2) <br />K = 42 GPM/psi'12 (60,5 LPM/bart12) <br />K = 5.6 GPM/psi'J2 (80,6 LPM/barl12) <br />K = 8.0 GPM/psi'l2 (116,8 LPM/bar'l2) <br /> <br />Temperature Ratings <br />16S'FI740C, 2120F/100oC, 2860F/1410C <br /> <br />Finishes <br />Sprinkler: White Polyester, Chrome <br />Plated, or Natural Brass <br /> <br />Corrosion Resistant Coatings <br />Sprinkler. Wax, Lead & Wax-over-Lead <br /> <br />* Head Guard & Water Shield: <br />G-2 (Guard) - (K=S.6 & K=8.0) Up & Pend. <br />WSG-2 (Guard & Shield) - (K=8.0) Up <br />WS-2 (Shield) - (K=S.6) Pendent <br />Factory Assembled Model A Pendent and <br />Model A MIL Shield. (K=S.6 & K=8.0) <br /> <br />(See Data Sheet 3-12.0 for details) <br /> <br />~ <br /> <br /> <br />[EI\ITRAL <br /> <br />..; ........ <br /> <br />"....... <br /> <br />I.' , '\.i~_:~" <br /> <br />f:: <br /> <br /> <br />;~ <br /> <br />s,_ <br /> <br />v~~ <br />~~ <br />. . ,~ <br />~J# <br />-S=='c~ <br />~ <br /> <br />III <br />. -r;1' --._..".'...:~ , <br />. .- _..c.:... <br /> <br />~~, .t, <br />~. '. . ..,.,:;:..... <br />..::~, ;'f';;'" <br />!'" ;-:---:.. <br />- .-. <br />~.- - . . ,'~.:o . <br />......... <br /> <br />-,...";~._/'.\-. <br />:..~.~:.. <br /> <br />Standard Spray <br />Upright & <br />Pendent <br />Sprinklers <br /> <br />Physical Characteristics <br />The Model A Upright & Pendent Sprin- <br />klers utilize a dezincification resistant <br />(DZR) bronze frame and a brass deflector. <br />The waterway is sealed with copper seal <br />disk, and the fusible assembly is con- <br />structed of bronze and stainless steel <br />components. <br /> <br />No. 1-1.0 <br />