My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
02-1688
Zephyrhills
>
Building Department
>
Permits
>
2002
>
02-1688
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:53:23 PM
Creation date
11/29/2006 11:36:46 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
02-1687
Building Department - Name
GOLD MEDALLION HOMES
Address
37340 PICKETTS MILL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />SUMMER POINT MULTIPLIERS (SPM) <br />6A-1 SUMMER OVERHANG FACTORS (SOF) FOR SINGLE AND DOUBLE PANE GLASS. <br /> <br />Ef <br />Un:: <br />~o <br />~l 0.793 0.709 0.588 0.547 0.479 0.431 0.396 <br />0.834 0.757 0.630 0.582 0.500 0.438 0.391 <br />0.857 0.798 0.708 0.674 0.616 0.570 0.532 <br />30' 3.5' 5.5' 6.5' 9.5' 14.0' 20.0' <br /> <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-2 WALL SUMMER POINT MULTIPLIERS fSPMl <br /> FRAME CONCRETEBLOCK(NORMAL~ FACE BRICK LOG <br /> INTERIOR EXT. R-VALUE WOOD FR R-VALUE BLOCK <br /> WOOD STEEL INSULATION NSUL 0-6.9 2.9 0-2.9 1.0 6 INCH 8 INCH <br />R-VALUE EXT ADJ EXT ADJ R-VALUE EXT ADJ EXT 7-10.9 .6 3-6.9 .6 R-VALUE EXT EXT <br />G-6.9 6.4 2.2 8.9 2.9 0-2.9 2.5 .9 2.5 11,18.9 .4 7-9.9 .4 0-2.9 1.7 1.0 <br />7-10.9 2.3 .8 4.1 1.3 3-4.9 1.4 .7 .7 19-25.9 .2 10&UP .2 ~.9 1.1 .8 <br />11-12.9 1.9 .7 3.0 1.0 5-6.9 1.0 .6 .3 26 & UP .1 7&Un .8 .7 <br />13-18.9 1.7 .6 2.8 0.9 7-10.9 .8 .4 .1 <br />19-25.9 1.0 .3 2.4 0.8 11-18.9 .4 .3 0 <br />26& Un .6 .2 1.3 0.4 19-25.9 .2 .2 I NOTE:SEESECTION2.00FAPPENDIXCFORMUlTIPUERS I <br /> 26 & Up .1 .1 OF ENVElOPE COMPONENTS NOT ON THIS FORI.l <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS (SPM) <br /> <br />6A-4 CEILING SUMMER POINT MULTIPLIERS fSPM) <br />UNDER ATTIC SINGLE ASSEMBLY CONCRETE QFCK ROOF <br />R-VALUE SPM R-VALUE SPM CEILING TYPE <br />19.21.9 2.82 10-10.9 10.27 R-VALUE EXPOSED DROPPED <br />22.25.9 2.55 11-12.9 9.73 10-13.9 11.13 10.40 <br />26.29.9 2.28 13'18.9 8.72 14-20.9 8.42 7.99 <br />30-37.9 2.13 19-25.9 6.90 21 &Up 5.99 5.76 <br />38 & Up 1.84 26.29.9 5.82 <br />RBS Credit 0.700 30 & Up 5.40 <br />IRCC Credit 0.864 <br />White ROOf Credit 0.550 <br /> <br />.' <br />~:s <br /> <br />DOOR TYPE EXTERIOR ADJACENT <br />WOOD 7.2 2.4 <br />INSULATED 4.8 1.6 <br /> <br />6A.S FLOOR SUMMER POINT MULTIPLIERS (SPM) <br />SLAB.:oN-GRADE RAISED ., RAISED WOOD <br /> POST OR PIER STEM WALL wi UNDER <br />EDGE INSULATION CONCRETE CONSTRUCTION FLOOR INSULATION ADJACENT <br />R-VALUE SPM R-VALUE SPM R-VALUE SPM SPM SPM <br />0-2.9 .31.9 0-2.9 -1.0 0-6.9 4.50 -5.8 5.3 <br />3'4.9 -31.8 3-4.9 .1.7 .. 7'10.9 2.28 -2.8 2.1 <br />5-6.9 .31.7 5.6.9 -1.7 11-18.9 1.83 .2.2 1.8 <br />7& Up .31.6 7 & Up .1.7 19& Up 1.36 -1.8 1.0 <br /> <br />6A-6 INFILTRATION & INTERNAL GAINS (SPM) 6A-8 DUCT MULTIPLIERS OM) See Tobto 6-10 for Code mnimt.mL <br />Air Infillralion 5.17 DUCT RETURN DUCTS In: <br />Internal Gains + 9.14 SUPPLY DUCTS IN: R-Value UncondiUoned AltlcJ AlticJ AlticJ Conditioned <br />Infiltration/lnlemaJ Gains 14.31 sDace RBS IRCC White roof space <br />(Combined) 4.2 1.113 1.107 1.108 1.107 1.103 <br /> Uncondilioned Space 6.0 1.087 1.081 1.083 1.081 1.0 '9 <br /> AIR HANDLER MULTIPLIERS SPM) 8.0 1.069 1.064 1.065 1.064 1.0 i2 <br />6A.7 4.2 1.072 1.066 -- -.. 1.0 1 <br />Located in garage 1.00 AtticlRadianl Barrier (RBS) 6.0 1.056 1.051 -- ,- 1.017 <br />Loca1ed in conditioned area 0.93 8.0 1.045 1.041 .- ... 1.038 <br />Located on exlerior of building '1.03 , AUlcllnlenor Ha<lIatlon 4.2 1.098 1.092 -.. 1. 4 <br />Loca ted in attic 1.05 Control Coatings (IRCG) 0.0 1.076 -- 1.071 --- 1. b <br /> 8.0 1.060 ,-- 1.057 --- 1. 2 <br /> 4:2 1.069 --- -- 1.06 1. l:l <br /> AUiClWhite Roof KO 1~:'2 ,-- .- 1.04 1. 4 <br /> 8.0 1.041 -- - 1.0 1.034 <br /> 4.2 UXJ6 1.005 1.007 1.003 1.000 <br /> Conditioned Space 6.0 UXJ5 1.004 1.005 1.002 1.000 <br /> 8.0 1.004 1.003 1.004 1.002 1.000 <br />6A-9 COOLING SYSTEM MULTIPLIERS (CSM) <br />SYSTEM TYPE See Table 6-3 lor Code rrinimums COOLING SYSTEM MULTIPLIERS ICSMl <br />Central Units (SEER) Rating 7.5-7.9 8.0-8.4 8.5-8.8 8.9'9.4 9.5-9.9 10.0-10.4 10.5-10.9 11.0-11.4 11.5-11.9 12.0-12.4 <br />CSM .45 .43 .40 .38 .36 .34 .32 .31 .30 .28 <br />PTAC & Room Units (EER) Rating 12.5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14.5-14.9 15.0-15.4 15.5-15.9 16.0-16.4 16.5-16.9 17.0-17.4 17.5 & UP <br />CSM .27 26 .25 .24 24 23 .22 21 .21 .20 .19 <br /> <br />FLORIDA BUILDING CODe - BUILDING <br /> <br />13.185 <br />
The URL can be used to link to this page
Your browser does not support the video tag.