<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> CHAPTER 4 - Commercial Building Compli~nce Methods CENTRAL
<br />FORM 400C-Ol
<br />Limited and Special Use Buildings Climate Zones 4 5 6
<br />Project Name: \) fC. F r n,,\<:,TC' IJ (" "\11 ....) IUr Zone: L\-
<br />Address: p C). C3,())( ~\t*-l Building Classification: OF="Fle~
<br />City, Zip Code: r;; 1), ,. \,' t 1'1\/ r:L ~~, ?:J ~~, (f) .~~ Building Permit No.:
<br />Builder: Permitting Office:
<br />Owner: Jurisdiction No.: ""2 , ,......:::. (", \ lDOO
<br /> 7. _ I ~ I \C
<br />WAllS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete ICBS Under Attic (n ? Slab-on-nrade \[,,17 Wood '7 2.(") Slnnle wall [,
<br />Wood frame I{nfnn Sinole Assemblv Raised Wood Metal Double wall
<br />Metal frame Other: Raised Concrete Insulated Sinnle roof
<br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDmONER HEATING "'YSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUIH TYPE
<br />Unitary & Heat Pump Central & Heat Pump Electric /
<br /><65,000 Btulh J.a. SEER ...L <65,000 Btulh ca3_ HSPF - Resistance / 0
<br />;'65,000 Btu/h _EER _IPLV - "65,000 Btulh _COP - Dedicated Heat Pu!pP" 0
<br />Water cooled _EER _IPLV - Water cooled _COP - Gas /' -
<br />Evaporatively cooled _EER - I;:vaporalively cooled _COP - Natural 0
<br />PTAC _EER - Electric Resistance _COP - LPG 0
<br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0
<br />Gas heat pump _COP - <225,0001300,000 Bluih _ AFUE - 01 0
<br />Other: ;,225,0001300,000 Btulh E,
<br />LIGHTING Total Lighting Wattage =--3.0(00 \,<;>q I SIZING CALCULATION I DUCTS R-value 67
<br /> = G2J Arne...
<br />Total Conditioned Floor Area \ (0 \"7- Wattslsq.ft. Attached Location
<br />
<br />~. PAESCAlPTIVE MEASUHES (Must be met or exceeded by all buildings.)
<br />~-
<br />Components Section Requirements Check
<br />Operations Manual 102.1 Operations manual will be provided to owner. ~--_._-- v
<br />Windows & Doors 406.1 Maximum: _3 elm oer sa.ft_ of window area' Maximum: 1.2 cfm oer so.ft_ of door area_ ./
<br />Joints/Cracks 406.1 To be caulked, aasketed, weatherstrlpped or otherwise sealed. /
<br />Dropped Ceiling Cavilv 406.1 Venled: seal and insulate ceiling (no T-bar celllnos!. Unvenled, no ceiling air barrier: seal and Insulate roof and side wails_ \/'
<br />Reheat 407.1 Electric resistance reheat prohibited_ -
<br />Ventilation 409_1 Supplied with readily accessible switch for shut-off andlor volume reducllon when ventilation Is not required. \/'
<br />HVAC Efficiency 407_1,408_1 Minimum efficiencies - Heating: Tables 4'7,4-8,4-9_ Cooling: Tables 4-3,4-4.4-5,4-6_ ./
<br />HVAC Controls 407.1 Separate readily accessible manual or automatic thermostat for each system_ /
<br />HV AC Ducts 410_1 Air duels, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated
<br /> and Installed In accordance with the criteria of section 410_ 1. v'
<br />Balancing 410_1 HVAC distribution system(s) tested and balanced_ ,/"
<br />Piping Insulation 411_1 In accordance with Table 4-11_ ./
<br />Water Heaters 412_1 Automatic electric storage water heaters ;S120 gallons and gas & oil fired storage water heaters ,;;75,000 Btulh shall meet
<br /> performance requirements In Table 4-12_ Eleclrlc > 120 gallons: standby loss S_30+27NT_ Gas >75,000, ON > 105.000: E. ,78, -
<br /> Standby loss S 1.30+114NT. Gas, 011 >155,000: E..78, Standby loss S 1_30+95/VT_
<br />Swimming Pools 412.1 Spas & heated pools must have covers_ Non-commercial pools musl have pump llmer_ Gas spa & pool heaters must
<br />& Spas have a minimum thermal efficiency of 78%_ -
<br />Hot Water Pipe 412_1 PipIng heat loss is limited to the levels In Table 4-11 for circulating systems and the first 8' of pipe from a storage
<br />Insulation tank. -
<br />Water Fixtures 412.1 Shower head water now restricted to maximum of 2.5 gpm at 80 psI. Toilets meet 42CFR 6295(k). Public lavatory fixture
<br /> maximum flow 01 .5 gpm; or if self-closing valve, _25 gallon circulating, .5 gallon non-circulating. .,/
<br />Lighllng 415.1 Ballasts shall have Power Factors no less than .90_ \/'
<br />
<br />If required by Florida law, I hereby certify that the syslem design Is in compliance with the Florida Energy Code_
<br />ARCHITECT: ART ::;,. \TZEL p, E
<br />ELECTRICAl SYSTEM DESIGNER:
<br />LIGHTING SYSTEM DESIGNER
<br />MECHANICAL SYSTEM DESIGNER:
<br />PLUMBING SYSTEM DESIGNER:
<br />
<br />Registration No.
<br />i="l ~: c:.,C?/.,"')&'
<br />
<br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology:
<br />Detached Buildings <200 sq. ft. 0 Convenience stores <5,000 sq. II.
<br />Skyboxeslsports stadiums 0 Restaurants <5,000 sq_ft_
<br />Traffic safety control towers 0 Retail stores <5.000 sq.ft.
<br />
<br />I hereby caftily thai the plans
<br />Florida Energy Code.
<br />
<br />PREPARED BV:
<br />I hereby certify thai Ihls
<br />
<br />OWNER AGENT:
<br />
<br />
<br />o
<br />o
<br />o
<br />
<br />Office buildings <5,000 sq.ft.
<br />School buildings <5,000 sq.ft.
<br />Storage buildings <5,000 sq. ft.
<br />
<br />~
<br />o
<br />o
<br />
<br />--- DATE: _--J2/.'t:.~.k
<br />nergy Code. 7-- 1'':'
<br />DATE:
<br />
<br />Review 01 ptans and specifications covered by (his calcutalion indicates comptiance with
<br />the Florida Energy Code. Belore construction is comp/eled. this building will be inspecled
<br />lor cOf'Jlpliance in accordance with Section 553_ 908. F .S.
<br />
<br />BUilDING OFFICIAL:
<br />DATE:
<br />