Laserfiche WebLink
<br />'. <br /> <br />CODE ANALYSIS -OFFICE FOR DR. FERNANDEZ <br /> <br />CODE DATE: FLORIDA BunDING CODE 2001 <br /> <br />GROUP: B-BUSINESS <br /> <br />CONSTRUcrION TYPE: TYPE V ORDINARY NON PROTECI'ED <br /> <br />NON-SPRINKLED <br /> <br />ACTUAL 1 ALLOWABLE AREA: DR FERNANDEZ= 3398 S.F. TOTAL BUILDING 6600 S.F.! ALWW ABLE <br />14,000 S.F. . <br /> <br />AREAI.HEIGHT INCREASES: NIA <br />'. ~ ~ <br /> <br />FIRE CONSTRUCTION REQUIREMENTS <br /> <br />EXTERIOR BEARING WALLS: NC <br />lNTERIORBEARlNG WALLS: NC <br />EXTERIOR NON BEARING W ALLS:NC <br />COLUMNS: NC <br />ROOF: NC CLASS A <br /> <br />OCCUPANT LOAD 3398/100=34 PEOPLE <br /> <br />EXIT WIDTH 34 X 0.2"=6.79" ACTUAL 140" <br />TRAVEL DISTANCE TO EXIT: LESS 'mAN 50' <br />MIN NO OF EXlTS.2 REQUIRED 14 SHOWN <br />MIN NO OF PLUMBING FIXTURES REQUIRED: 2 W.C., 2 LA VS <br />DRlNK.ING FOUNTAINS REQUIRED: 1 D.F. <br />MOP SINKS REQUIRED: I MOP SINK <br />SPECIAL REQUIREMENTS: MIN 2 HOUR RATED WALL BETWEEN TENANTS <br />FIRE EXTINGUISHERS REQUIRED: 2-2AI0BC LOCATED AS DIRECfED BY FIRE MARSHALL <br />SMOKE DETECTORS REQUIRED: IN HALLWAYS WIRED TO AlC SYSTEM <br />EMERGENCY LIGHfING REQUIRED: YES- SEE PLANS <br /> <br /> <br />~ <br />(N)1J-U-VT 11 <br />