Laserfiche WebLink
<br />. ' <br /> <br />WINTER POINT MULTIPLIERS (WPM) <br />GA- 10 WINTER OVERHANG FACTORS (WOF) <br /> <br />l <br />Wa: 1. , <br />;;:0 Southwest 1.00 1.002 1.013 1.038 1.071 1.f18 1.168 1225 1.278 1.388 1.490 1.573 <br />~L West 1.00 0.999 1.003 1.013 1.025 1.040 1.053 1.067 LOn 1.095 U07 1116 <br />Northwest 1.00 0.999 0.998 0.997 0.997 0.996 0.995 0.994 0.993 0.992 0.990 0.989 <br />OH Len Ih 0.0' 1.0' 1.5' 2.0' 3.0' 3.5' .4.5' 5.5' 6.5' 9.5' 14.0' 20.0' <br /> <br /> <br />CUMA TE ZONES 4 5 G <br /> <br />GA-ll WALL WINTER POINT MUrnPLlERS (WPM) <br /> FRAME CONCRETEBLOCKlNORMALWTl FACE BRICK LOG <br /> INTERIOR EXT. R-V ALUE WOOD FR R-VALUE BLOCK <br /> WOOD STEEL INSULATION INSUL D-6.9 7.0 0-2.9 3.7 6 INCH 8 INCH <br />R-VALUE EXT ADJ EXT ADJ R-VALUE EXT ADJ EXT 7-10.9 2.1 3-6.9 2.6 R-VALUE EXT EXT <br />D-6.9 6.8 5.3 9.4 6.7 0-2.9 6.0 3.1 6.0 11-18.9 1.7 7-9.9 1.8 0-2.9 2.2 12 <br />7-10.9 2.5 2.1 4.4 3.3 3-4.9 3.8 2.3 2.8 19-25.9 1.0 10 & UP 1.3 3-6.9 1.2 .9 <br />11-12.9 2.0 1.8 3.3 2.6 5-6.9 2.9 1.9 2.0 26& Up .6 7&Up .9 .7 <br />13-18.9 1.8 1.6 3.0 2.4 7-10.9 2.3 1.5 1.5 <br />19-25.9 1.1 1.0 2.6 2.2 11-18.9 1.5 1.1 .8 <br />26& Un .7 .7 1.4 1.2 19-25.9 .8 .7 r NOTE:SEESECTION2.0OFAPPENOIXCFORMULTIPlIERS 1 <br /> 26 & Uo .5 .5 OF ENVaOPE COMPONENTS NOT ON THIS FOAM. <br /> <br />::1 <br /> <br />GA- 12 DOOR WINTER POINT MULTIPLIERS WPM) GA-13 CEILING WINTER POINT MULTIPLIERS (WPM) <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE aECK ROOF <br /> R-VALUE WPM R-V ALUE WPM CEIUNG TYPE <br />WOOD 7.6 5.9 19-21.9 .87 10-10.9 1.02 R-VALUE EXPOSED DROPPED <br /> 22-25.9 .78 11-12.9 .96 10-13.9 U6 1.05 <br />INSULA TED 5.1 4.0 26-29.9 .69 13-18.9 .84 14-20.9 .83 .76 <br /> 30-37.9 .64 19-25.9 .62 21&Up .54 .50 <br /> 3B & Un - .55 26-29.9 .50 <br /> RSS Credit 0.850 30 & Up .46 <br /> IRCC Credit 0.905 <br />GA-14 flOOR WINTER POINT MULTIPUERS (WPM) White Root Credit 1.044 <br />SLAB-ON-GRADE RAISED RAISED WOOD <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wi UNDER ADJACENT <br />.<: CONSTRUCTION flOOR INSULATION <br />R-VALUE WPM R-VALUE WPM R-VALUE WPM WPM WPM <br />0-2.9 2.5 0-2.9 4.0 D-6.9 2.49 1.8 5.3 <br />3-4.9 -L7 3-4.9 1.8 7-10.9 0.78 .7 2.1 <br />5-6.9 .2.4 5-6.9 U ll-18.9 0.47 .5 1.8 <br />7 & Un -2.7 7 & Un' .8 19 & IJD 0.14 .3 10 <br /> <br />GA-15 INFIL TRA TION & INTERNAL GAINS (WPM) GA-17 DUCT MULTIPLIERS DMI See TabletHO'orCodomi1imun.. <br />Air Infiltration 0.87 DUCT RETURN DUCTS In: <br />Internal Gains -1.15 SUPPLY DUCTS IN: R-Value Unconditioned Attic! Attic! Attic! Conditioned <br />Infiltration/Internal Gains -0.28 SDace RBS IRCC White roof so ace <br />(Combined) 4.2 1.107 1.098 UOO 1.102 1.092 <br /> Unconditioned Space 6.0 To rg- 1':07 urn 1.075 1.068 <br /> AIR HANDLER MUL TIPUERS (WPM) 8.0 Hi 1 IJl5i 1.057 1.058 1. 002 <br />GA-16 4:2 1.06 1.06 - - 1.059 <br />located in oaraoe 1.00 AIlicIRadiant Barrier (RBS) 61f 1. ilf TIl5 - -- 1.045" <br />Located in conditioned area 0.93 If.O T. 16 Jl)41 -- -- 1.036 <br />located on exterior of building - 1.03 4.2 1. fT - 1.088 -- 1.07 <br />located in attic 1.05 AllicIlnterior Radiation G:O 1. '3" - T.Oillf --- 1."US <br /> Conlrol Coatinas fJRCC) 8.0 T. IT - 1-:052 - 1.04 <br /> 4.2 1.120 - -- 1.110 1.09 ,- <br /> Attic'White rool 6lY" 1. ~ - - LOBI U]10 <br /> 8.0 1. 18 - - U163 1.054 <br /> 42 T 19 1:0 lIDO 1.009 1.000 <br /> Conditioned Space 6]f 1. 17 1:0 . 1:001 TOO7 1.000 <br />GA-la HEATING SYSTEM MULTIPUERS (HSMI 8."0 1. l5" 1:0 T.OO6 1.005 1.000 <br />SYSTEM TYPE See Tallies 6-6 b 6-8IllfCOde IIiniruns HEATING SYSTEM MUlTIPUERS (H SUI <br />Ceolral Heal HSPF 6.40-6.79 6.80-6.89 6.90-7.39 7..ro-7.89 7.90-8.39 8.40-8.89 8.9-9.39 9.4-9.89 <br />Pump Units HSM .53 .50 .49 .4G .43 .41 .38 .36 <br /> HSPF 9_90-10.39 10.40- 10.89 10.90-11.39 11.40-11.89 11.90- 12.39 12.40 &m <br /> HSM _. .34 .33 .31 .30 .29 28 <br />PTHP .. COP 2.50-2.69 2.70-2.89 - 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90....19 <br /> HSM .40 .37 .34 .32 .30 .29 27 .26 <br />Electric Strip & Gas 1.0 (for gas cmdit muJtiprNllS, see Table 6A-211 <br /> <br />FlORIDA BUILDING CODe - BUILDING <br /> <br />13.187 <br />