My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-1944
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-1944
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:09:10 PM
Creation date
12/14/2006 9:52:59 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-1944
Building Department - Name
CHILIS
Address
7643 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />SPECIFICATIONS <br />Primary (AC) Power <br />. FCPS-24F: 120 VAC 50/60 Hz, 2.0 A max. <br />. FCPS-24FE: 220/240 V AC 50/60 Hz, 1.0 A max. <br />. Wire size: minimum #14 AWG (2.0 mm2) with 600V <br />insulation. <br />Control Input Circuit <br />. Trigger Input Voltage: 9.0 to 32 VDC. <br />. Trigger Current: 2.0 mA (16 - 32 V). <br />(per input) 1.0 mA (9 - 16 V). <br />Trouble Contact Rating <br />. 5 amps at 24 VDC. <br /> <br />TERMINAL DESIGNATIONS <br /> <br />Auxiliary Power Output <br />. Specific Application Power - 45 mA Short Circuit. <br />Output Circuits <br />. +24 VDC (19.1 - 26.4) filtered, regulated. <br />. 3.0 amps maximum for anyone circuit. <br />. 4.0 amps maximum total continuous current for all outputs <br />(Stand-alone mode). <br />. 6.0 amps maximum total short-term current for all outputs <br />(NAC Expander mode). <br />Secondary Power (Battery) Charging Circuit <br />. Supports lead acid batteries only. <br />. Float Charge Voltage: 27.6V. <br />. Maximum Charge Current: 250 mA. <br />. Maximum Battery Capacity: 7.0 AH. <br /> <br />- - -- <br />~~NN):"):"~~NN):"):" <br />aJ G) G1 Q) It) Q) 4:l l1) 4) G) Q) CD <br />~~~~~~~~~~~~ <br />(!1.(!1.(!1.(!1.(!1.(!1.(!1.(!1.(!1.(!1.(!1.(!1. <br />+1+1+1+1+1+1 <br />...-.....,........NNC"') (l")C"')M",-.:r <br />'53'5:;:5'5'5'5'5'5'5"5 <br />.9-.9-.9-.9-.9-.9-.9-.9-.9-.9-.9-.9- <br />:::J ~ ::J ::J :'j ::J ::J ::J ::J ::J ::J ::J <br />000000000000 <br /> <br />TB4_ <br />1 2 3 4 5 6 7 8 9 10 11 12 <br /> <br />TO TRANSFORMER #2 <br />TO TRANSFORMER #1 <br /> <br />~ <br />~ '0 <br />.I:: Z :r <br />"5l u u <br />w <( <( <br /> <br />11IIII TB 1 <br /> <br />P1 4P 4P <br />~I 4P 4P <br />lill 4P 4P <br />~ 4P 4P ......................:...~ 8 I <br />~ . i:0 <br /> <br />~I~OO <br />[: <br /> <br />=.J <br /> <br />FCPS-24F(E) <br /> <br />-- <br />\iiiiii' <br />\iiiiii' <br />-- <br /> <br />)JP1 <br />P3 ()===-() Battery fuse 10A 3AG slow blow <br />m ~ ! R27 <br />'TB2~ ~ 0 000000 <br /> <br />R134 <br /> <br />~ ~u <br />.!.. ...!..o <br />~ ~> <br />.!! G) 'II:t <br />- - '" <br />~ ~:r- <br /><( <br />.... <br /> <br />o:s~~~~~ <br />u ~::J:J::J:J :J <br /><(.I::,geeee <br />1:~f-f-f-f- <br />caii;;..-NM""" <br />~ 21'5 '5 '5 '5 <br />~jg~~~~ <br />~~oooo <br />u.!!l <br /><(0; <br />ell <br /> <br />ORDERING INFORMATION <br /> <br />FCPS-24F Remote charger power supply (120 VAC). <br />Includes main printed circuit board, transformers, <br />red enclosure, and installation instructions (use <br />FCPS-24 for gray enclosure). <br /> <br />FCPS.24FE Remote charger power supply (220/240 VAC). <br />Includes main printed circuit board, transformers, <br />red enclosure, and installation instructions (use <br />FCPS-24E for gray enclosure). <br /> <br />Page 2 of 3 - DA-45858 <br /> <br />R175 <br />- <br /> <br />R76 <br />- <br /> <br />1 <br />JP2(,031 <br />1 <br /> <br />I~ <br /> <br />4 <br />5'r. <br />6 <br />7 <br />8 <br />9 <br /> <br />TB3 <br /> <br />R176 <br />- <br /> <br />R63 <br />- <br />- <br /> <br />A77-716B <br /> <br />PS.1270 <br />MPM-4F <br /> <br />Notes: <br /> <br />1) Cut JP1 to use a UL listed external <br />battery charger, or MPM-4F ammeter/ <br />voltmeter. <br /> <br />2) Cut R 134 to delay AC loss report- <br />ing for 8 hours (24-hour standby), or <br />cut R 134 and R76 to delay AC loss <br />reporting 16 hours (50-hour standby). <br /> <br />3) Cut R175 to make output #2 non- <br />resettable in stand-alone mode. <br /> <br />4) Cut R176 to make output #4 non- <br />resettable in stand-alone mode. <br /> <br />IN + <br />(Contro/lnput #1 from FACP) <br />IN- <br />OUT + / Trouble Contact <br />OUT- <br />Trouble Contact <br />IN + <br />IN _ (Contro/lnput #2 from FACP) <br /> <br />Auxiliary Output (+24 VDC, 45 mA max.) <br />Common <br /> <br />MPM-4F <br /> <br /> <br />12/24 VOC end-of-Iine relay for monitoring <br />four-wire smoke detector power. <br />Battery, 12 volt, 7.0 AH (two required). <br />Optional ammeter/voltmeter. Mounts in <br />FCPS backbox. <br />
The URL can be used to link to this page
Your browser does not support the video tag.