My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-1944
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-1944
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:09:10 PM
Creation date
12/14/2006 9:52:59 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-1944
Building Department - Name
CHILIS
Address
7643 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ing plate: 5" (127 mm) wide x 5-5/8" (142.875 mm) high x 1-5/16" <br />(33.338 mm) deep. <br />Weight, horn only: 7.2 oz. (204 g). <br />Weight, strobe and horn/strobe: 8.8 oz. (250 g). <br /> <br />Mounting: standard boxes 4" x 4" x 1-1/2" deep (101.6 x 101.6 x <br />38.1 mm) or 2" x 4" x 1-7/8" deep (50.8 x 101.6 x 47.625 mm). <br />Operating temperature, indoor: 320F to 1200F (OOC to 490C). <br />Weatherproof models, horn and horn strobes: 320F to 1500F <br />(OOC to 660C); outdoor strobe only: -40oF to +1580F (-40oC to <br />+700C); ULC Canadian models: -40oC to +660C. <br />Maximum humidity: 95% as tested per UL 464. <br />Voltages: 12 or 24 VDC and FWR unfiltered. <br />Operating voltage range:* 12-volt models: 10.5 - 17 V. 24-volt <br />models: 20 - 30 V. With Sync-Circuitâ„¢ module MOL *: 12-volt <br />models: 11 - 17 V. 24-volt models: 20 - 30 V. See current draw <br />tables on page 4. <br />- These products should be operated within their rated voltage range. <br />UL does, however, test functional integrity to -20% and +10% of <br />manufacturer's stated ranges. <br />U.S. Patent Numbers: 5,593,569. 5,914,665. 6,049,446. <br /> <br />ENGINEERING SPECIFICATIONS <br /> <br />General - SpectrAlert@ horns, strobes and horn/strobes shall <br />be capable of mounting to a standard 4" x 4" x 1-1/2" (101.6 x 101.6 <br />x 38.1 mm) backbox or a single-gang 2" x 4" x 1-7/8" (50.8 x 101.6 <br />x 47.625 mm) backbox using the universal mounting plate included <br />with each SpectrAlert@ product. Also, SpectrAlert@ products, when <br />used in conjunction with the accessory Sync-Circuitâ„¢ Module, shall <br />be powered from a non-coded power supply and shall operate on <br />12 or 24 volts. 12-volt rated devices shall have an operating volt- <br />age range of 10.5 - 17 volts. 24-volt rated devices shall have an <br />operating voltage range of 20 - 30 volts. SpectrAlert@ products <br />shall have an indoor operating temperature range of 320F to 1200F <br />(DOC to 490C) and operate from a regulated DC or full-wave recti- <br />fied, unfiltered power supply. <br /> <br />Horn - Horn shall be a System Sensor SpectrAlert@ model <br />capable of operating at 12 and 24 volts. Horn shall be <br />Listed to UL 464 for fire protective signaling systems. The horn <br />shall have two tone options, two audibility options (at 24 volts) and <br />the option to switch between a temporal 3 pattern and a non-tem- <br />poral continuous pattern. All horn models shall operate on a coded <br />power supply. <br /> <br />Strobe - Strobe shall be a System Sensor SpectrAlert@ model <br />Listed to UL 1971 and be approved for fire protective <br />service. The strobe shall be wired as a primary signaling notifica- <br />tion appliance and comply with the Americans with Disabilities Act <br />requirements for visible signaling appliances, flashing at 1 Hz over <br />the strobe's entire operating voltage range. The strobe light shall <br />consist of a xenon flash tube and associated lens/reflector system. <br /> <br />Horn/Strobe Combination - Hom/strobe shall be a Sys- <br />tem Sensor SpectrAlert@ model Listed to UL 1971 and <br />UL 464 and shall be approved for fire protective service. Horn/ <br />strobe shall be wired as a primary signaling notification appliance <br />and comply with the Americans with Disabilities Act requirements <br />for visible signaling appliances, flashing at 1 Hz over the strobe's <br />entire operating voltage range. The strobe light shall consist of a <br />xenon flash tube and associated lens/reflector system. The horn <br />shall have two tone options, two audibility options (at 24 volts) and <br />the option to switch between a temporal 3 pattern and a non-tem- <br />poral continuous pattern. Strobes shall be powered independently <br />of the sounder with the removal of factory-installed jumper wires. <br />The horn on horn/strobe models shall operate on a coded or non- <br />coded power supply (the strobe must be powered continuously). <br /> <br />Module - Module shall be a System Sensor Sync-CircuiFM model <br />Listed to UL 464 and shall be approved for fire protec- <br />tive service. The module shall synchronize SpectrAlert@ strobes <br />at 1 Hz and horns at temporal 3. Also, the module shall silence the <br />horns on horn/strobe models. while operating the strobes, over a <br />single pair of wires. The module shall be capable of mounting to a <br />4-11/16" (119.063 mm) square x 2-1/8" (53.975 mm) deep backbox <br />and shall control two Style Y (Class B) or one Style Z (Class A) <br />circuit. Module shall be capable of multiple zone synchronization <br />by daisy-chaining multiple modules together and resynchronizing <br />each other along the chain. The module shall NOT operate on a <br />coded power supply. <br /> <br />SOUND OUTPUT GUIDE UL Reverberant Room dBA @ Volts DC Anechoic Room Peak dBA @ 10 ft./VDC <br /> (dBA) 10.5 12 17 20 24 30 10.5 12 17 20 24 30 <br /> LOW Ele ctro me chanical NA NA NA 75 75 79 NA NA NA 94 96 98 <br /> TONE 3000 Hz Interrupted NA NA NA 75 79 79 NA NA NA 94 96 98 <br />Temporal Electromechanical 75 75 79 82 82 82 94 95 98 100 101 102 <br /> HIGH <br /> TONE 3000 Hz Interrupted 75 75 79 82 85 85 94 95 98 100 101 102 <br /> LOW Electromechanical NA NA NA 79 82 85 NA NA NA 94 96 98 <br />Non. TONE 3000 Hz Interrupted NA NA NA 82 82 85 NA NA NA 94 96 98 <br />Temporal HIGH Electromechanical 79 79 85 85 88 88 94 95 98 100 101 102 <br /> TONE 3000 Hz Interrupted 79 82 85 88 88 88 93 95 98 100 101 102 <br /> <br />5939soun.tbl <br /> <br />NOTES FOR PRODUCT LINE INFORMATION ~ <br /> <br />NOTES: 1) Canadian model numbers end in "AU. 2) Latin American model numbers end in 'F". 3) All weatherproof models must use <br />weatherproof backbox model WBB. 4) All SpectrAlert@ products are designed for wall-mount only. 5) Installation of less than 75 candela <br />strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However. it is the responsibility of the person or <br />entity deSigning the fire alarm system to determine the acceptability of less than 75 candela strobes. 6) All 15/75 candela strobes or homl <br />strobes are recommended for 20' x 20' (6.096 x 6.096 m) rooms or less. -For a complete listing of SpectrAlert current requirements, please refer <br />to the Current Draw tables on page 4 of this document, or the Instruction Manual. Horn and horn/strobe current draws assume the horn is set at <br />Temp 3, electromechanical tone, and high audibility. <br /> <br />Page 2 of4 - DA-46540' 01/12/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.