<br />ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS SECTION 2 <br />Table 2.3 Schedule of Post to Beam Size and Number of Thru-Bolts Required <br /> Aluminum Alloy 6063 T-6 <br /> Beam Minimum I # Thru-Bolts @ L=D+'J.R I Minimum M,Inlmum # <br /> Size Post Size I 1/4R. 318" . I Knee Brace" Knee Brace Screws <br />Hollow Sections <br />2R x 3R x 0.050" Hollow Tlltl3" x 3"x 0.060" Scalloped I 2 I - I 2" x 3" x 0.050" (3) m3 <br />2R x 4R X 0.050R Hollow 13" x 3" x 0.060" Scalloped 2 I - I 2" x 3" x 0.050' I (3) m3 <br />Self Mating Beams <br />2R x 4" x 0.038" X 0.100 3" x 3"x 0.060' Scalloped 2 - 2" x 3" x 0.050' (3) m3 <br />2" x 5" x 0.050" X 0.100 3" x 3"x 0.060" Scalloped 2 - 2" x 3" x 0.050" (3) m3 <br />2" x 6" x 0.050" X 0.120 3" x 3"x 0.060" Scalloped 2 - 2" x 3" x 0.050" (3 #10 <br />2" x 7" x 0.055" X 0.120R 3" x 3" x 0.093' 3 2 2" x 4" x 0.050" (3 #10 <br />2R x 8" x o.on" x 0.224R 3" x 3" x 0.093' 3 2 2" x 4" x 0.050' (3 #12 <br />,,~. " x 0.224R 3" x 3" x 0.125" 4 3 2" x 4" x 0.050' (3 #14 <br />2" x 9" x 0.082" x 0.306" 3" x 3" x 0.125" 4 3 :t"X .... X 0.o5OI 3 #14 <br />2" x 10R x 0.092" x 0.369" 4" x 4" x 0.125" 6 4 2" x 4" x 0.050" (4) #14 <br />The minimum number of thru bolts Is (2) <br />" Minimum post/beam may be used as minimum kn_ brace <br />Table 2.4.1 Footings" Maximum Roof Area for Attached Carport Posts <br /> Wind Zone. 100 MPH 110 MPH 120 MPH 123 MPH 130 MPH 140 MPH 150 MPH <br /> Attached Cover UDlift . " 20 iIISF 24 iIISF 29 iIISF 30.5 iIISF 34 iIISF 39 iIISF 45 iIISF <br /> Free-Standlna Cover UDIIft a 10 iIISF 11 #lSF 13 #lSF 13.3 iIISF 17 #lSF 20 #lSF 23 #lSF <br />Existing Slab on Grade with unknown 20 18 15 14 13 11 10 <br /> reinforcement <br />Isolated Footing Uplift Maximum Attributable Roof Anla In Square Feet <br />Dimension.- RatIng (Ibs.) <br />1'.()" x 1'.()" X 1'.()R 520 26 21 18 17 15 13 11 <br />1'-4" x 1'-4R x 1'-4R 1000 50 41 34 33 29 26 22 <br />1'-6" x 1'-6R x 1'-6R 1320 66 55 45 43 39 34 29 <br />1'-8" x 1'-8" x 2'.()" 2040 102 85 70 67 60 52 45 <br />1'-8" x 1'-8" x 2'-6R 2540 127 106 88 84 75 65 57 <br />2'.()" x 2'.()" X 2'.()R 2640 132 110 91 87 78 68 59 <br />2'.()R x 2'.()" x 2'-6" 3300 165 138 114 108 97 85 73 <br />2'-6" x 2'-6R x 2'-6" 4000 230 191 158 151 135 118 102 <br />2'-6" x 2'-6" x 3'.()" 4800 276 230 190 181 162 141 123 <br />Notes: <br />1. Isolaled Fooling is a poured concrete rectangular solid (Length x Width x Depth). <br />2. Slab on grade must be new or in good condition. <br />3. For tree-standing covers multiply the above root areas by 2.0. <br />Pre-Cast Block Footing <br />Pre-cast footing block ( 16" x 16R x 4" ) at 24R below grade with 80 tI bag pre-mlx concrete and backfilled to grade. <br /> Maximum Attributable Roof Area In Square Feet <br /> 100 MPH 110 MPH 120 MPH 123 MPH 130 MPH 140 MPH 150 MPH <br />Dimensions Uplift Rating (Ibs.) 20 iIISF 24 iIISF 29 #lSF 30.5 tllSF 34 iIISF 39 ii/SF 45 #lSF <br />1 x 80# Bag 1,734 87 72 60 57 51 44 38 <br />2 x 80# Bag 1,819 91 76 63 59 54 46 40 <br />3 x 80# Bag 1,904 95 79 66 62 56 49 42 <br />Note: Maximum uplift on post is determined by mu/tipying maxlmum attributable roof area x applied load. <br />Example: Post tributary root area = 77', Applied load for 110 MPH wind zone = 24#1Sq. Fl, Uplift on post = 77 x 24 = 1,540# <br />" Root areas are based on attached cover uplift loads. <br /> Lawrence E. Bennett, P. E. <br /> CIVIL ENGINEER - DEVELOPMENT CONSUL TANT <br /> P.O. BOX 04368, SOUTH DAYTONA. FL 32121 <br /> TELEPHONE (386) 707-4774 <br /> FAX (386) 767-6556 <br /> SEAL <br />@ COPYRIGHT 2002 PAGE <br />'~OT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRfTTEN PERMISSION OF LAWRENCE E BENNETT, P.E. 2-41 <br />"-- <br />