My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2010
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:08:52 PM
Creation date
12/18/2006 8:30:43 AM
Metadata
Fields
Template:
Building Department
Permit #
03-2010
Building Department - Name
CHILIS BAR & GRILL
Address
7643 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ANSUL:~; <br /> <br />FEATURES <br /> <br />. UL and ULC Listed - Meets Requirements <br />of UL 300 <br /> <br />. Overlapping Appliance Protection <br /> <br />. Two Nozzle Styles Cover All Hazards <br /> <br />. Dual Agent <br /> <br />. Rapid Flame Knockdown <br /> <br />. New Proprietary Agent With Increased <br />Performance <br /> <br />. Fifteen Times Faster Than Existing Agents <br />in Reducing the Temperature of the Grease <br />Below the Reflash Point <br /> <br />. Reliable Cartridge Operated <br /> <br />. Aesthetically Appealing <br /> <br />APPLICA liON <br /> <br />The PIRANHA,. Restaurant Fire <br />Suppression System is an automatic, pre- <br />engineered, fixed. fire suppression system <br />designed to protect the following areas asso- <br />ciated with cooking equipment; ventilating <br />equipment including hoods, ducts. plenums, <br />and filters; fryers; griddles and range tops; <br />upright, natural charcoal. or chain-type broil- <br />ers; Electric. lava rock. mesquite or gas-radi- <br />ant char-broilers and woks. <br /> <br />The system is ideally suitable for use in <br />restaurants. hospitals, nursing homes. hotels, <br />schools, airports. and other similar facilities. <br /> <br />Use of the PIRANHA Restaurant system is <br />limited to interior applications only. The regu- <br />lated release and tank assemblies must be <br />mounted in an area where the air tempera- <br />ture will not fall below 32 OF (0 OC) or exceed <br />130 OF (54 oC). The system must be <br />designed and installed within the guidelines <br />of the UL Listed Design. Installation. <br />Recharge, and Maintenance Manual. <br /> <br />SYSTEM DESCRIPTION <br /> <br />The PIRANHA Restaurant Wet Agent Fire <br />Suppression system is a dual-agent, pre- <br />engineered. fixed. automatic fire extinguish- <br />ing system developed specifically for <br />improved fire protection of commercial <br />restaurant cooking appliances, exhaust <br />hoods and ducts. <br /> <br />The PIRANHA system is available in 3 sizes: <br /> <br />PIRANHA-7 (1.5 gallon, 7 nozzle capacity) <br /> <br />PIRANHA-10 (2.25 gallon. 10 nozzle <br />capacity) <br /> <br />PIRANHA-13 (3.0 gallon, 13 nozzle <br />capacity) <br /> <br />When actuated, the system discharges a <br />fixed amount of proprietary wet chemical <br />agent followed by water through the same <br />nozzles. Water is provided by a connection <br />to the potable water supply. Advantages of <br /> <br />r"lr :/-~ <br />/~~~~:~~-~~~~~ <br />// ~ --- ~~~ ~...-----:r"""";r-:'~'JJ- <br />'~~ .--/ ~~J.<::--::~g-~-"'/ <br />~::-i?fl;f:~~I~---1--!/~7 <br /> <br />[ ,,~ ,<. I' ...........~......- // <br />-~ --- ~------t~:: :,~ '..i ~;:::"/Y' /// <br />-..:--, '-,..::...;-?;/ // .. <br />" ' /........-: ~/ <br />,__ /' I // <br />"~ I // <br /> <br />.'.l- L~y'''//- <br /> <br /> <br />. /:v/ <br />/</F <br />,--;/ <br />L~;:>/ <br /> <br />RESTAURANT <br />FIRE <br />SUPPRESSION <br />SYSTEMS <br />DATA SHEET <br /> <br /> <br />- , <br />---::;:',--/ <br /> <br />(~ <br /> <br />the dual system over single wet agent sys- <br />tems include: (1) more robust suppression of <br />hostile fires in protected restaurant hazards; <br />(2) greater hazard area protection with less <br />wet agent; (3) faster flame extinguishment <br />and securement of hot fuels such as cooking <br />shortening; (4) overlapping protection of <br />cooking appliances from fixed nozzle spac- <br />ings, allowing appliances to be interchanged <br />freely without changing nozzles; (5) more <br />rapid cooling of hot fuels and appliances to <br />prevent reignition; (6) simplicity of design and <br />installation, <br /> <br />The addition of the water discharge signifi- <br />cantly aids in increasing and prolonging the <br />foam blanket generated by the wet chemical <br />agent. The longer retention of the foam blan- <br />ket allows the hot grease to cool well below <br />the auto-ignition temperature. <br /> <br />Patents are pending for both the new propri- <br />etary wet chemical agent and the dual agent <br />system itself, <br /> <br />The wa ter spray portion of the system is pro- <br />vided by a connection to the potable water <br />supply. <br /> <br />The system design for appliance protection <br />under the hood allows the nozzles to be <br />positioned uniformly from one end of the <br />appliance line to the other. Most appliances <br />under the hood can be protected in this over- <br />lapping manner, therefore, it is not necessary <br />to protect each appliance individually. <br />Appliances are free to be shifted around <br /> <br /> <br /> <br />001551 <br /> <br />under the hood. The only exception to this <br />overlapping type coverage are upright broil- <br />ers. salamanders. and chain broilers. <br /> <br />These type appliances requires dedicated <br />nozzle protection. <br /> <br />The system is capable of automatic detection <br />and actuation and/or remote manual actua- <br />tion, Additional equipment is available for <br />mechanical or electrical gas line shut-off <br />applications. <br /> <br />The detection portion of the fire suppression <br />system allows for automatic detection by <br />means of specific alloy rated fusible link <br />detectors, which, when the temperature <br />exceeds the rating of the link, the link <br />separates, allowing the regulated release <br />to actuate. <br /> <br />A system owner's guide is available contain- <br />ing basic information pertaining to system <br />operation and maintenance. A detailed tech- <br />nical manual is also available including <br />system description, design, installation, <br />recharge, and maintenance procedures, plus <br />additional equipment installation and <br />resetting instructions. <br /> <br />The system is installed and serviced by <br />authorized distributors that are trained by the <br />manufacturer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.