Laserfiche WebLink
<br />I nsta lIation <br /> <br /> <br />Genesis horns and strobes mountto any <br />standard one-gang surface orflush electrical <br />box. Matching optional trim plates accommo- <br />date one-gang, two-gang, four-inch square, or <br />octagonal boxes, and European 1 OOmm square. <br /> <br />All Genesis signals come pre-assembled with <br />captive mounting screws for easy installation. <br />Two tabs at the top ofthe signal unlock the <br />cover to reveal the mounting hardware. The <br />shallow depth of Genesis devices leaves ample room behind the <br />signal for extra wiring. Once installed with the cover in place, no <br />mounting screws are visible. <br /> <br />Genesis Horn/Strobe <br />with optional trim plll'le <br /> <br />Field Configuration <br />Temporal horn and horn/strobe models are factory setto sound in <br />a three-pulse temporal pattern. Units may be configured for use <br />with coded systems by snipping the circuit board as shown in the <br />Jumper Locations diagram at right. This results in a steady output <br />that can be turned on and off as the system applies and removes <br />power to the signal circuit. A Genesis Signal Master is required <br />when horn/strobe models are configured for coded systems. <br /> <br />Jumper Locations <br /> <br />To change horn from <br />temporal to steady <br />cut from circle J 1 <br />to edge of circuit board <br /> <br />To change strobe from <br />steady to temporal <br />cut from circle J2 <br />to edge of circuit board <br />" <br />./ <br /> <br />(' <br /> <br />" <br />~\ <br /> <br />\. <br /> <br />!/ <br /> <br /> <br />o <br /> <br />Note: Use temporal strobe configuration for private mode <br />applications only. <br /> <br />Genesis strobe-only and combination temporal horn/strobe <br />models may be configured for temporal flash. This battery-saving <br />feature is intended for private mode signaling only. To set the <br />device for temporal flash, snip the circuit board as shown in the <br />Jumper Locations diagram above. <br /> <br />Non-temporal, horn-only models sound a steady tone. For field- <br />selectable steady or temporal output, use a temporal horn. <br /> <br />Wiring <br /> <br />Field wiring is connected to Genesis signals with terminals that <br />accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. <br />Horns, strobes, and combination horn/strobes are interconnected <br />with a single pair of wires as shown below. <br /> <br />Specifications <br /> <br />e <br /> <br /> <br /> <br />To next device <br />or end of line <br />device <br /> <br />Polarity shown in <br />alarm condition <br /> <br />.{ <br /> <br />e <br /> <br />Nole: Strobes must have continuous voltage. <br /> <br />Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. <br />Flash tube enclosure Clear polycarbonate <br />Mounting Flush mount: 2% inch (64 mm) deep one-gang box <br />Surface mount: EST model 27193 surface mount box, wiremold box, or equivalent surface-mount box <br />(indoor wall mount only) With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box <br />Wire Connections Two screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size <br />Operating environment 32-120oF (0-490C) ambient temperature. 93% relative humidity <br />Agency UL 1971, UL 1638, UL 464, ULC S525, ULC S526, MEA. FM, CSFM, CE, FCC. <br />Listings/Approvals (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) <br />Dimensions (HxWxD) Signal: 4-1/2" x 2-3/4' x 13/16' (113 mm x 68 mm x 21 mm) <br />Trimplate: 5" (127 mm); Height - 57/8" (149 mm); Depth - W (13 mm) <br /> Strobes: 20 - 31 Vdc filtered continuous only <br />Operating Voltage ,20 - 24 Vdc FWR (full wave rectified) continuous only <br />Horns: 20 - 31 Vdc filtered continuous (or coded when horn set to continuous - non temporal - output) <br /> 20-24 Vdc FWR continuous (or coded when horn set to continuous - non temporal - output) <br />Strobe output rating UL 1971, UL 1638, ULC S526: 15 cd, 30 cd, 60 cd, 75 cd or 110 cd <br /> Self-synchronized: one flash per second within 200 milliseconds over 30 minutes on common circuit. <br />Strobe flash rate With optional Signal Master: one flash per second within 10 milliseconds indefinitely. <br /> Temporal setting (private mode only): synchronized to temporal output of horns on the same circuit. <br /> Temporal Horn: Synchronized at temporal rate within 200 milliseconds over thirty minutes on common circuit. With <br />Horn pulse rate optional Signal Master, synchronized at temporal rate within 10 milliseconds indefinitely. <br /> Horn: Continuous only. <br />Temporal audible pattern % sec ON, % sec OFF, % sec ON, % see OFF, % see ON, 1% see OFF, then repeat cycle <br /> <br />Page 4 of 6 <br /> <br />EDWARDS SYSTEMS TECHNOLOGY <br />Uterature Sheet #85001-0629 <br />~....+ ..... h_ I...an f....r 1..-+_11_+1,..... ......r........__. <br /> <br />Issue 6 <br />