Laserfiche WebLink
<br />Options <br /> <br />Panel Operation <br /> <br />Operators' Interface <br />Control of the panel's operation is both simple and intuitive. While <br />the LEOs and optional LCD are visible with the panel door closed, <br />the door and bezel block access to the controls. With the door <br />open the following controls are available: <br /> <br />Reset - used to reset the panel; <br /> <br />Signal Silence and Drill- used to silence <br />notification appliances or activate the drill <br />function; <br /> <br />Panel Silence -silences the buzzer on the panel <br />and the remote trouble unit; <br /> <br />Remote Disconnect-disables the DACT, or, if no <br />DACT installed, disables the panel's alarm relay; <br /> <br />Walk Test -activates the panel's silent and <br />audible walk test mode. <br /> <br />Thefollowing system LEOs display the panel's status: <br /> <br />Alarm - panel is in the alarm state; <br /> <br />Trouble - panel is in the trouble state; <br /> <br />Supervisory- panel is in the supervisory state; <br /> <br />Power - indicates the status ofthe AC power <br />source; <br /> <br />. Disable - indicates when any IDC, NAC, relay or <br />the DACT are disabled; <br /> <br />Annunciator Trouble - indicates trouble on the <br />remote annunciator bus; <br /> <br />Battery Trouble - indicates battery or <br />charging problems; <br /> <br />Ground Fault - indicates a short between any <br />panel circuit and ground; <br /> <br />Walk Test - indicates that one or more IOCs <br />are in the walk test mode; <br /> <br />Alarms Silenced - indicates thatthe panel is <br />in the alarm state with one or more NACs <br />silenced. <br /> <br />Off-premise communication <br />A fully integrated FkeShield DACT/dialer is available for reporting <br />events to a monitoring facility. The DACT also supports uploading <br />or downloading of system configuration,statusand event history. <br />The OACT is programmable for either single or dual line opera- <br />tion.ltalso supports split and dual reporting for two <br />digital alarm receivers. <br /> <br />The DACT brings additional features to the panel <br />including a 32-character alphanumeric LCD displav, <br />local or remote PC programming and an event <br />history Jog. <br /> <br />Modules are also available for City Tie (CTM4.7) and <br />Reverse Polarity (RPM) connections. <br /> <br />Remote Annunciators and Relays <br />The serial bus standard on all FireShield models is <br />another installation time-saver. This circuit allows the <br />connection of Remote System Indicators (FSRSI), <br />Remote Zone Indicators (FSRZI-A) and Remote Relay <br />Modules (FSRRM) over a four-wire (data and power) <br />circuit Annunciator and relay modules can be <br />installed up to 1,000 feet from the panel on 18-gauge <br />wire. <br /> <br />FS1004 <br /> <br /> <br />Application <br /> <br />FireShield provides smoke and fire detectio n, <br />occupant notification and off-premises signaling for <br />small- to medium-sized buildings. <br /> <br />Each IDC can be configured for either Class B or <br />Class A operation and one of eight operating modes: <br /> <br />Alarm -without smoke detector verification; <br /> <br />Alarm - with smoke detector verification, and <br />instant activation of contact devices; <br /> <br />Waterflow Alarm - no retard; <br /> <br />Waterflow Alarm - with 15 seco nd retard; <br /> <br />Combination Waterflow (no retard) and Supervi- FS502 <br />sory; <br /> <br />Combination Waterflow (retard) and Supervisory; <br /> <br />Supervisory (Latching); <br /> <br />Monitor -for monitoring devices other than alarm <br />or supervisory such as fire doors or tire dampers. <br /> <br />NACs may also be configured for either Class B or <br />Class A operation. Additionally, NACs can be <br />individually configured for one ofthree outputs. <br />These are Genesis, Continuous or Temporal. The <br />Genesis selection allows ind ependent horn control <br />over two wires and provides precision synchroniza- <br />tion for Genesis devices, all withoutthe need for a <br />Genesis Signal Master accessory. <br /> <br />When configured for Genesis notification appliances, <br />FireShield's Alarm Silence function will silence <br />connected Genesis audible appliances but Genesis <br />strobes will remain active until the panel is reset. <br />When Genesis Mode is selected, both the horns and <br />strobes on Genesis and Enhanced Integrity notifica- ,i' <br />tion appliances will be synchronized across all NAGs. <br /> <br /> <br />Each IDC has a disable switch and three LEDs: <br />Alarm -red - indicates that the IDC is in the alarm <br /> <br />state; <br /> <br />Trouble - yeffow - indicates that the IDC is in the <br />tro uble state oris disabled (when flashing); <br /> <br />Superviso rylMonitor -yellow - ind icates that the <br />IDC is in the supervisory state orthe monitor state <br />(when flashing). <br /> <br />Each NAC also has a disable switch and a troublel <br />disable LED. <br /> <br />Status indication with the DACT IDia/er installed <br />The dialer's LCD display provides two lines x '6 <br />characters oftert For programming, the top line <br />displays the programming step and the lower line <br />displays the selected option. <br /> <br />Page 2 of e <br /> <br />laaue 2 <br /> <br />EDWARDS SYSTEMS TECHNOLOGY <br /> <br />literature Sh_t #85005-0118 <br />Not 1'0 be used for installaTion purposes. <br />For the most: current IIteratu.re end update. vlalt 'WW'W'...'t.net:; <br />