Laserfiche WebLink
<br />~;l /1 <br /> <br />Page 1 <br /> <br />Residential Heat Loss and Heat Gain Calculation <br />In accordance with ACCA Manual J <br /> <br />01/27/2003 <br /> <br />Report Prepared By: <br /> <br />Chris' AlC Company <br />13033 US Hwy 301 <br />Dade City FL <br />(352) 521-4977 <br /> <br />Fax: (352) 521-3393 <br /> <br />For: <br /> <br />Gold Medallion Homes / Savanna <br />Lot# 09 Silver Oaks Village <br />Pasco County Silver Oaks Village, FI <br /> <br />Design Conditions: Ocala <br /> <br />Indoor: <br />Summer temperature: 75 <br />Winter temperature: 72 <br />Relative humidity: 55 <br /> <br />3 <br /> <br /> Outdoor: <br /> Summer temperature: 93 <br /> Winter temperature: 34 <br /> Summer grains of moisture: 116 <br /> Daily temperature range:Medium <br />Sensible Latent Total Total <br />Gain Gain Heat Gain Heat Loss <br />(BTUH) (BTUH) (BTUH) (BTUH) <br />26,198 2,192 28,390 49,146 <br /> ( 2.5 tons) <br />26,198 2,192 28,390 49,146 <br />2(3,198 2,192 28,390 49,146 <br />972 1,502 2,474 3,358 <br />2,382 0 2,382 2,340 <br />900 690 1,590 0 <br />'1,200 0 1,200 0 <br />0 0 0 6,710 <br />(i,088 0 5,088 13,521 <br />H8 0 178 220 <br />222 0 222 276 <br />222 0 222 276 <br />222 0 222 276 <br />1.18 0 118 146 <br />2,954 0 2,954 7,849 <br />446 0 446 331 <br /> <br />Building Component <br /> <br />Whole House <br /> <br />1,636 sq.ft. <br /> <br />First Floor <br />All Rooms <br />Infiltration <br />Duct <br />People <br />Miscellaneous <br />Floor <br />NWall <br />Window <br />Window (2) <br />Window (3) <br />Window (4) <br />Window (5) <br />SWall <br />Window <br /> <br />1,636 sq.ft. <br /> <br />1,636 sq.ft. <br />697.7 sq.ft. <br />8 sq.ft. <br />10 sq.ft. <br />1 0 sq. ft. <br />10 sq.ft. <br />5.3 sq.ft. <br />405 sq.ft. <br />12 sq.ft. <br />