Laserfiche WebLink
<br />1815.5 Segmental Retaining Walls. Segmental retaining <br />walls shall be designed in accordance with NCMA Design <br />Manual for Segmental Retaining Walls <br /> <br />SECTION 1816 <br />TERMITE PROTECTION <br /> <br />1816.1 Termite Protection. Termite protection shall be pro- <br />vided by registered termiticides, including soil applied pesti- <br />cides, baiting systems, and pesticides applied to wood, or <br />other approved methods of termite protection labeled for use <br />as a preventative treatment to new construction. See Section <br />202, REGISTERED TERMITICIDE. ~pon completion of <br />lli.e <Ipplir<ltion of the termite protective treatment, a <br />Certificate of Compliance shall be issued to the building <br />department by the licensed pest control companv that con- <br />tains the following statement: fThe building has received a <br />complete treatment for the prevention of subterranean ter- <br />mites_ Treatment is in accordance with rules and laws estab- <br />lished by the Florida Department of Agriculture and <br />Consumer Services.") <br /> <br />1816.1.1 If soil treatment is used for subterranean termite <br />prevention, the initial chemical soil treatment inside the <br />foundation perimeter shall be done after all excavation, <br />backtIlling and compaction is complete, <br /> <br />1815.5 - TABLE 1815.4 <br /> <br />1816.1.2 If soil treatment is used tor subterranean termite <br />prevention, soil area disturbed after initial chemical soil <br />treatment shall be retreated with a chemical soil treatment, <br />including spaces boxed or tomled. <br /> <br />1816.1.3 If soil treatment is used for subterranean termite <br />prevention, space in concrete floors boxed out or tormed <br />for the subsequent installation of plumbing traps, drains or <br />any other purpose shall be created by using plastic or <br />metal permanently placed forms of sufficient depth to <br />eliminate any planned soil disturbance after initial chemi- <br />cal soil treatment. <br /> <br />1816.104 If soil treatment is used for subterranean termite <br />prevention, chemically treated soil shall be protected with <br />a minimum 6 mil vapor retarder to protect against rainfall <br />dilution. If rainfall occurs betore vapor retarder place- _ <br />ment, retreatment is required. Any work, including place- <br />ment of reintorcing steel, done after chemical treatment <br />until the concrete floor is poured, shall be done in such <br />manner as to avoid penetrating or disturbing treated soil. <br /> <br />1816.1.5 If soil treatment is used tor subterranean termite <br />prevention, concrete overpour or mortar accumulated <br />along the exterior foundation perimeter shall be removed <br />prior to exterior chemical soil treatment, to enhance verti- <br />cal penetration of the chemicals. <br />- <br /> <br />TABLE 1815.4 <br />REINFORCEMENT FOR MASONRY RETAINING WALLsa <br /> <br />Nominal Wall Reinforcement size & spacing for equivalent fluid <br />Wall depth, weight of soil, pcf (kNlm3), of: <br />thickness, H, ft (m) <br />in. (mm) 30 (4.7) 45(7.1) 60 (9.4) <br />8 (203) 4.0 (1.2) #4 @ 64 in. #4 (ii! 40 in. #4 @ 32 in. <br /> 4.7 (1.4) #4 @ 40 in. #4 (~. 24 in, #4 @ 16 in. <br /> 5,3 (1.6) #4 @ 24 in. 114@. 16 in #5 @ 16 in. <br /> 6.0 (1,8) #5 @ 24 in. #6 Iii!. 16 in. #8 @ 16 in. <br /> 6.7(2.0) #5 @ 16 in, #6@ 8 in. = <br />10 (254) 4.0 (1.2) #4 @ 72 in. #4 @ 64 in. #4 @ 48 in. <br /> 4.7(1.4) #4 @ 56 in. #4 @. 40 in. 114 @ 24 in. <br /> 5.3 (1.6) #4 @ 40 in, #4 @ 24in. #4 @ ]6 in_ <br /> 6.0 (1.8) #4 @ 24 in. #4@ 16in. #5 @ 16 in_ <br /> 6.7 (2.0) #4@ 16 in. #5 @ 16 in. #6@16in_ <br /> 7.3 (2_2) #5 @ 24 in. #6@ 16 in. #6@ 8 in. <br /> 8.0 (2.4) #5 @ 16 in. #6@ 8 in. = <br />12 (305) 4.0 (L2) #4 @ 72 in, #4 Iii!. T2 in. #4 @. 64 in. <br /> 4.7 (1.4) #4 @ 72 in. 114 (ZiJ. 48 in. #4 @ 40 in. <br /> 5.3 (La) #4 @ 48 in. 114 @ 32 in. #4 @ 24 in. <br /> 6.0 (1.8) #4 @ 32 in. 114 @ 24in. #4 @. 16 in. <br /> 6.7 (2.0) #4 @ 24 in. 114@ 16 in. #5@16in. <br /> 73 (2.2) #4(;1), 16 in, #5@ 16 in. #6 @ 16 in. <br /> S.O (2.4) #5 @. 24 in, #5@ 16 in. #7IZiJ. 16 in. <br /> S.712.7) #5 (QJ 16 in. 117@ 16 in. #7@ Sin. <br /> 93 (2,S) #6 @. 16 in_ 1171ilj 8 in. = <br /> <br />a hased on fully grouted masonry; f'm = 1500 psi (10.3 MPa); d = 5 in.. 7 in, Clnd 9 in. (127,178 ma 229 mm) tor wall thicknesses ofS, 10, and 12 <br />(203.254, and 305 mm), respectively: level backfill to top of wall. <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />18.21 <br />