Laserfiche WebLink
<br />.. <br /> <br />SCREEN, ACRYLIC I VINYL, GLASS & MODULAR ROOMS <br /> <br />COMPOSITE ROOF PANELS: <br />(4) 1/4" x 4" LAG BOLTS W/ <br />1-1/4" FENDER WASHERS P~~R <br />4~0"PANELACROSSTH~ <br />FRONT AND 24" O.C. ALONG <br />SIDES <br /> <br />2" x 2" OR 2" x 3" HOLLOW <br /> <br />GIRT AND KICK PLATE 2" x 2" <br />HOLLOW RAIL <br /> <br />POST ATTACHED TO BOTTOM <br />/ MIN, (3) #10 x 1-1/2" S.M.S. IN <br />SCREW BOSSES <br /> <br />r <br /> <br /> <br /> <br />.......... <br /> <br />SECTION 3 <br /> <br />RISER PANELS ATTACHED PE <br />CHAPTER 7 <br /> <br />HEADER ATTACHED TO POST <br />W/ MIN. (3) #10 x 1-1/2" S.M.S, <br />IN SCREW BOSSES <br /> <br />2" x 2",2" x 3" OR 3" x 2" <br />HOLLOW (SEE SPAN TABLES) <br /> <br />FOR SNAP EXTRUSIONS GIRT <br />ATTACHED TO POST WITH <br />MIN. (3) #10 x 1/2" S.M.S. IN <br />SCREW BOSSES <br /> <br />1" x 2" OPEN BACK BOTTOM <br />RAIL <br /> <br />1/4" x 2-1/4" MASONRY <br />ANCHOR @ 6" FROM EACH <br />POST AND 24" O.C. (MAX,) <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER - DEVELOPMENT CONSUL T ANT <br />P.O. BOX 214368, SOUTH DAYTONA. FL 32121 <br />TELEPHONE (386) 767-4774 <br />FAX (386) 767-6556 <br /> <br />PAGE <br /> <br />@ COPYRIGHT 2003 <br />NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E BENNETT, P.E. <br /> <br />c. <br /> <br /> <br /> <br />L <br />" <br />~ <br /> <br /> <br />TYPICAL UPRIGHT DETAIL <br />SCALE: 3" = 1 '-0" <br /> <br />3-17 <br />