Laserfiche WebLink
<br />FOR.M 600A-2001 <br /> <br />SUMMER CALCULATIONS <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: 23rd street, zephyrhills, FL, <br /> <br />PERMIT #: <br /> <br /> BASE AS..BUIL T <br />GLASS TYPES <br />.18 X Conditioned X BSPM = Points Overhang <br /> Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points <br />.18 240.0 25.78 1113.7 Double, Tint N 1.0 5.0 13.0 20.63 0.96 258.2 <br /> Double, Tint W 1.0 5.5 16.2 40.60 0.96 632.4 <br /> As-Built Total: 29.2 890.6 <br />WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points <br />Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 512.0 1.70 870.4 <br />Exterior 512.0 1.90 972.8 <br />Base Total: 512.0 972.8 As-Built Total: 512.0 870.4 <br />DOOR TYPES Area X BSPM = Points Type Area X SPM = Points <br />Adjacent 0.0 0.00 0.0 <br />Exterior 0.0 0.00 0.0 <br />Base Total: 0.0 0.0 As-Built Total: 0.0 0.0 <br />CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points <br />Under Attic 240.0 2.13 511.2 Under Attic 30.0 240.0 2.13X 1.00 511.2 <br />Base Total: 240.0 511.2 As-Built Total: 240.0 511.2 <br />FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points <br />Slab 64.0(p) -31.8 -2035.2 Slab-On-Grade Edge Insulation 0.0 64.0(p) -31 .90 -2041.6 <br />Raised 0.0 0.00 0.0 <br />Base Total: -2035.2 As-Built Total: 64.0 -2041.6 <br />INFIL TRA TION Area X BSPM = Points Area X SPM = Points <br /> 240.0 14.31 3434.4 240.0 14.31 3434.4 <br />Summer Base Points: 3996.9 Summer As-Built Points: 3665.0 <br />Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling <br /> Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points <br /> (DM x DSM x AHU) <br /> 3996.9 0.4266 1705.1 3665.0 1.00 1.000 0.407 1.000 1491.9 <br /> <br />EnergyGauge 1M DCA Fonn 6OOA-2001 <br />