Laserfiche WebLink
<br />,> <br /> <br />I <br />.. <br />~ <br /> <br />bS(XJ lJJ./ <br /> <br /> <br />AAMA/N\VWDA 101/I.S.2-97 <br />TEST REPORT SUlVIl\1ARY <br /> <br />Rendered to: <br /> <br />SIMONTON WINDOWS <br /> <br />SERIES/l\tIODEL: 75-75 <br />TYPE: PVC Double Hung Windows <br />(with A2 Reinforcement and Slotted Cavity Plugs) <br /> <br />.... <br />"."" <br /> <br /> Results <br />Title of Test Test Specimen #1 Test Specimen #2 Test Specimen iB <br />Rating H-LC25 56 x 84 H-LC35 52 x 71 H-LC55~ 36 x 72 <br />Overall Design Pressure 25 psf 35 psf 55 psf <br />. Operating Force 34 Ibs max. N/A N/A <br />Air Infiltration <0.08 cfmlft' N/A N/A <br />Water Resistance 5.25 psf N/A 8.25 psf <br />Structural Test Pressure 37.5 psf 52.5 psf 82.5 psf <br />Deglazing Passed N/A N/A <br />Forced Entry Resistance Passed N/A N/A <br /> <br />Reference should be made to Report No. 05-30308.01 for complete test specimen descriBtion and <br />. data. <br /> <br />For ARCHITECTURAL TESTING, INC. <br /> <br />.; <br /> <br />;R~~ <br /> <br />. Lynn George, Project Manager <br />LG:nlb <br />