<br />FORM 600A-2001
<br />
<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />ADDRESS: Lots 1 Eucalyptus Drive, Zephyrhills, FL, 33540-
<br />
<br />PERMIT #:
<br />
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
<br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sa.ft. window area; ,5 cfm/sa.ft. door area. I
<br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & top/bottom plates; between walls and floor,
<br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> from, and is sealed to, the foundation to the top plate.
<br />Floors 606.1,ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed I
<br /> to the perimeter. penetrations and seams, I
<br />Ceilings 606.1,ABC.1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, I
<br />I
<br /> soffits. chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> installed that is sealed at the perimeter, at penetrations and seams.
<br />Recessed Lighting Fixtures 606.1 ,ABC,1 ,2.4 Type IC rated with no penetrations. sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from I
<br /> conditioned space, tested,
<br />Multi-story Houses 606.1,ABC,1,2,5 Air barrier on perimeter of floor cavity between floors, I
<br />Additional Infiltration reqts 606.1,ABC,1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, I
<br /> , h<lvC combustion air, __
<br /> -, '-=- . .. ...,.,....""".,. ~ - -"'" --
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.)
<br />COMPONENTS SECTION REQUIREMENTS I CHECK
<br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit I
<br /> breaker (electric) or cutoff (aas) must be orovided, External or built-in heat trap reauired,
<br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools !
<br />I
<br /> must have a pump timer, Gas spa & pool heaters must have a minimum thermal I
<br /> i efficiency of 78%,
<br />Shower heads 612.1 i Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. !
<br />Air Distribution Systems 610,1 ! All ducts. fittings, mechanical equipment and plenum chambers shall be mechanically I
<br /> ! attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
<br /> ! Ducts in unconditioned attics: R-6 min. insulation.
<br />HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system, I
<br />I
<br />Insulation 604.1, 602,1 I Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. !
<br /> Common ceiling & floors R-11, ,
<br />
<br />EnergyGaugeâ„¢ DCA Form 600A-2001
<br />
<br />EnergyGauge@/FlaRES'2001 FLRCNB-31
<br />
|