Laserfiche WebLink
<br />I <br />. <br />~ <br /> <br />05-30327.01 <br />Page 3 of3 <br /> <br />Test Results: (Continued) <br /> <br />Paragraph <br /> <br />Title of Test - Test Method <br /> <br />Results <br /> <br />Allowed <br /> <br />2.1.7 <br /> <br />Welded Comer Test <br /> <br />Meets as stated <br /> <br />Meets as stated <br /> <br />2.1.8 <br /> <br />Forced Entry Resistance per ASTM F 588-97 <br /> <br />Hand Manipulation Test <br /> <br />No entry <br /> <br />No entry <br /> <br />Optional Performance <br /> <br />4.3 <br /> <br />Water Resistance per ASTM E 547 <br />WTP = 6.75psf No leakage <br /> <br />No leakage <br /> <br />4.4.2 <br /> <br />Uniform Load Structural <br />@ 67.5 psf (positive) <br />@ 67.5 psf (negative) <br /> <br />No damage <br />No damage <br /> <br />No damage <br />No damage <br /> <br />Detailed drawings, representative samples of the test specimen, and a copy of this report 'will be. <br />retained by A TI for a period of rour years. The above results were secured by using the <br />designated test methods and they indicate compliance with the performance requirements of the <br />above referenced specification. This report does not constitute certification of this product, <br />which may only be granted by the certification program administrator. <br /> <br />For ARCHITECTURAL TESTING, INe: <br /> <br />i?~~ <br /> <br />~IfA. J~ <br /> <br />Digitally signed by Lynn George <br /> <br />Lynn George <br />Project Manager <br /> <br />Scott A. Warner <br />Executive Vice President <br /> <br />LG:nlb <br />05-30327.01 <br />