Laserfiche WebLink
<br />FORM 600A-2001 <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br /> <br />Project Name: <br />Address: <br />City, State: <br />Owner: <br />Climate Zone: <br /> <br />Legend 30 Driftwood <br />Lots 15 and 16 Eucalyptus Drive <br />Zephyrhills, FL 33540- <br />Driftwood Spec #15 <br />Central <br /> <br />Builder: <br />Permitting Office: <br />Permit Number: <br />Jurisdiction Number: <br /> <br />1. New construction or existing <br />2. Single family or multi-family <br />3. Number of units, if multi-family <br />4. Number of Bedrooms <br />5. Is this a worst case? <br />6. Conditioned floor area (ft2) <br />7. Glass area & type <br />a. Clear - single pane <br />b. Clear - double pane <br />c. Tint/other SHGC - single pane <br />d. Tint/other SHGC - double pane <br />8. Floor types <br />a. Slab-On-Grade Edge Insulation <br />b. N/A <br />c. N/A <br />9. Wall types <br />a Concrete, Int Insul, Exterior <br />b. Frame, Wood, Adjacent <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. Under Attic <br />c. N/A <br />II. Ducts <br />a. Sup: Unc. Ret: Unc. AH: Interior <br />b. N/A <br /> <br />New <br />Single family <br />I <br />2 <br />No <br />1239 ft2 <br /> <br />202.8 ft2 <br />0.0 ft2 <br />0.0 ft2 <br />0.0 ft2 <br /> <br />R=O.O, 154.0(p) ft <br /> <br />R=4.2, 907.0 fT-' <br />R=I1.0, 81.0 ft2 <br /> <br />R=30.0, 409.0 ft2 <br />R=30.0, 830.0 ft2 <br /> <br />Sup. R=6.0, 75.0 ft <br /> <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 29.3 kBtu/hr <br />SEER: 12.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 29.3 kBtulhr <br />HSPF: 7.80 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br /> <br />a. Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0,90 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HV AC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF-Whole house fan, <br />PT -Programmable Thermostat, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />Glass/Floor Area: 0.16 <br /> <br />Total as-built points: 16373 <br />Total base points: 17230 <br /> <br />PASS <br /> <br /> <br />I hereby certify that the plans and specifications covered <br />by this calculation are in compliance with the Florida <br />Energy Code. <br /> <br />PREPARED BY: &~ ~~Aff~ <br />DATE: 7-~/-05 <br /> <br />I hereby certify tha: this building, as designed, is in <br />complianc orida Energy Code. <br /> <br />AGENV ~~ <br /> <br />OWNE <br />DATE: <br /> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br /> <br />(; <br /> <br />EnergyGauge@ (Version: FLRCNB-31) <br />