My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2501
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2501
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:06:25 PM
Creation date
1/10/2007 2:24:40 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-2501
Building Department - Name
GHD
Address
38217 EUCALYOTUS DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />.FORM 600A-2001 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: Lots 15 and 16 Eucalyptus Drive, Zephyrhills, FL, 33540- <br /> <br />PERMIT #: <br /> <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sa.ft. window area; .5 cfm/sa.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; I <br />I <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility I <br /> ! penetrations; between wall panels & top/bottom plates; between walls and floor. I <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the too olate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter, oenetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, I <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; I <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the oerimeter, at oenetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> , I conditioned so ace, tested. <br />Multi-story Houses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavitv between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion ai~ - <br /> - .....""'.. - - -~ - - -. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION I REQUIREMENTS CHECK <br />Water Heaters 612.1 ! Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit I <br /> breaker (electric) or cutoff (oas) must be provided. External or built-in heat trao reauired. I <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools I <br /> I must have a pump timer. Gas spa & pool heaters must have a minimum thermal I <br /> efficiencv of 78%. I <br />Shower heads 1612.1 Water flow must be restricted to no more than 2.5 Qallons per minute at 80 PSIG. ! <br />Air Distribution Systems ! 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically I <br /> I attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. 1-- <br />HVAC Controls i 607.1 i Seoarate readilv accessible manual or automatic thermostat for each system. <br />Insulation 604.1, 602.1 I Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-2001 <br /> <br />EnergyGauge@/FlaRES'2001 FLRCNB-31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.