My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2519
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2519
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:06:17 PM
Creation date
1/11/2007 8:57:24 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-2519
Building Department - Name
CITY OF Z-HILLS
Address
3940 SOUTH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ROBBINS ENG. GENERAL NOTES & SYMBOLS <br /> <br />PLATE LOCATION <br /> <br />--I 1-- 108 <br /> <br />~ <br /> <br />6.3 x 8.8 <br /> <br />PLATE SIZE <br /> <br />LATERAL BRACING <br /> <br />Cen ter plates on joi n ts <br />unless otherwise noted in <br />plate list or on drawing. <br />Dimensions are given in <br />inches (i.e. 1 1/2" or 1.5") or <br />IN-16ths (i.e. 108). <br /> <br />PLATE ORIENTATION <br /> <br />The first dimension is the <br />width measured perpen- <br />dicular to slots. The second <br />dimension is the length <br />measured parallel to slots. <br /> <br /> <br />lx4 continuous lateral bracing <br />attached with (2) 8d nails each <br />member where indicated or 2x4 <br />"T" or "L' brace stiffener if <br />applicable nailed flat to edge of <br />web with 12d nails spaced 8" O.c. <br />"T" or "L' brace must be extended <br />at least 90% of web lengdl. <br /> <br />DIMENSIONS <br /> <br />BEARING <br /> <br />When shown, indicates <br />direction of slots in <br />connector plate. <br /> <br />6-08-08 <br />. I <br /> <br />I'" <br /> <br />708 <br />1-1 <br /> <br />ROBBINS LOCK connector plates (20 ga. galv, steel <br />ASTM A653 SS Grade 40) shall be applied on both <br />faces of truss at each joint, Center the plates, unless <br />shovm otherwise by circles (0) or dimensions. No <br />loose knots or wanes in plate contact area, Splice <br />only where shown, Overall spans assume 4" bearings <br />at each end, unless indicated otherwise, Cutting and <br />fabrication shall be performed on equipment which <br />produces snug-fitting joints and plates, Unless <br />otherwise noted, moisture content of lumber shall <br />not exceed 19% at time of fabrication and these <br />designs are not applicable for use with fire retardant <br />lumber, This design was prepared in accordance with <br />"National Design Specifications for Stress - Grade <br />Lumber and Its Fastenings" (AFPA), "Design <br />Specifications for Light Metal Plate Connected \Vood <br />Trusses" (TPI), and HUD Design Criteria for <br /> <br />All dimensions are shown in ~ \\~len truss is designed to <br />FT-IN-SX (i.e. 6' 8 1/2" or bear on multiple supports, <br />6-08-08). Dimensions less interior bearing locations <br />than one foot are shown in should be marked on the <br />IN-SX only (i,e, 708). truss. Interior support or <br />~ temporary shoring must be <br />in place before erecting this <br />truss, If necessaf)', shim <br />bearings to assure solid <br />con tact wi th truss. <br /> <br />Trussed Rafters. Robbins Eng. Co, bears no <br />responsibility for the erection of trusses, field bracing <br />or permanent truss bracing. Refer to HIB-91 as <br />published by the Truss Plate Institute, 583 D'Onofrio <br />Drive, Suite 200, Madison, \'~sconsin 53719, Persons <br />erecting trusses are cautioned to seek professional <br />advice concerning proper erection bracing to prevenr <br />toppling and "dominoing", Care should be taken to <br />prevenr damage during fabrication, storage, shipping <br />and erection, Top and bottom chords shall be <br />adequately braced in the absence of sheathing or rigid <br />ceiling, respectively, I t is the responsibili ty of others <br />to ascertain that the design loads utilized on this <br />drawing meet or exceed the actual dead loads <br />imposed by the structure and the live loads imposed <br />by the local building code or historical climatic records, <br /> <br />/, <br />FURNISH A COPY OF THIS DESIGN TO ERECTION C0'lNTRACTOR. IT IS THE RESPONSIBILITY <br />/f. <br />OF BUILDING DESIGNER TO REVIE\VTHIS DR'-'TG, & VERIFY THAT DATA <br />INCLUDING DIM. & LOADS CONFORM TO ARCH. PLAN/SPECS & FAB. TRUSS LAYOUTS. <br /> <br /> <br />I CORPORATE HEADQUARTERS I <br /> <br />P.O, Box 280055 <br />Tampa, FL 33682-0055 <br />800-282-1299 · Fax: 813-971-6117 <br />
The URL can be used to link to this page
Your browser does not support the video tag.