My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2520
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2520
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:06:17 PM
Creation date
1/11/2007 8:58:55 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-2520
Building Department - Name
CITY OF Z-HILLS
Address
6118 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />/..V <br />eo <br /> <br />.. <br />TECHNICAL DATA FOR <br />STEEL WEB STOPPERS@ FOR SMOKE DETECTORS <br />PART NO. STI9601 - FOR LOW PROFILE ~ <br />PART NO. STI 9609 - FOR HIGH PROFILE <br />PART'NO. STI 8110- FOR SURFACE-MOUNTING <br /> <br />LOW PROFILE DETECTOR COVER L- <br />PART NO. STI 9601 ,~ <br /> <br /> <br />I <br />~ ~ <br />N N <br /> <br />~- <br />"'-i!l <br /> <br />if <br /> <br />:=:Ll <br />lL :~:: =bJj <br /> <br />~ <br /> <br />FRONT VIEW <br /> <br />TOP VIEW <br /> <br />HIGH PROFILE DETECTOR COVER <br />PART NO. STI 9609 <br /> <br /> <br />N to <br />;::, Ul <br />... ... <br /> <br />" <br /> <br />~ L 3.-1 <br /> <br />81/2' <br />.._- 8314' <br /> <br />JJ <br /> <br />FRONT VIEW <br /> <br />TOP VIEW <br /> <br />OPTIONAL STAND-OFF <br />SPACERS FOR SURFACE MOUNTED <br />DETECTORS 1 1/4' X 3/4" o.d. X 1/4" i.d. <br />SMOKE DET~CTOR I ;--1 <br /> <br />o-~_I "---C--l-.... <br />- +;;. ('~=:==...---" ~-'-7? <br />~ /""7""",\ L_U--- <br /> <br /> <br />~\( () .J <br />O~~.- . ~c-~_ 0- ~" .,_ <br />- ----c ~-: <br /> <br />------- <br />--'~""""@ <br /> <br />_ DETECTOR <br />/--- PROTECTOR <br /> <br /> <br />. . --""'@ <br /> <br />--..."'''tii) <br /> <br />PRINTED IN U.S.A <br /> <br />A damaged smoke detector could make an <br />entire fire alarm system inoperable and <br />negate the early warning response for <br />which it was intended. To maintain critical <br />credibility, it may be necessary to install a <br />physical guard to prevent damage by acci- <br />dent or vandalism. STl's Steel Web <br />Stoppers for Smoke Detectors do exactly <br />that. <br /> <br />NOTE: These devices should only be used <br />in areas where abuse of smoke detectors <br />is causing false fire alarms or high mainte- <br />nance costs. <br /> <br />· Web-like design that copies the master <br />builder of nature--the spider. <br />· Heavy-duty steel construction to take <br />tough knocks in stride. <br />· Two models that fit virtually all smoke <br />detectors <br />· L.E.D. indicator remains visible. <br />· Easy installation and easy removal for <br />servicing detectors. <br />· Aesthetically appealing. <br />· Tamperproof screws available. <br />· Can be spray painted prior to installa- <br />tion once without affecting UL listing. <br />· Generically listed for ANY UL listed <br />detector. <br />· State of California Listed. <br /> <br />...,.(\) <br /> <br />INSTALLATION <br />Two types of mounting are available. <br />Flush-mounted means the smoke detector <br />is mounted directly on the ceiling. <br />Surface-mounted means the detector is <br />mounted on an electrical box away from <br />the ceiling or other surface. Tamper proof <br />screws and bit available. <br /> <br />FLUSH-MOUNTED <br />1. Center Steel Web Stopper around detec- <br />tor. <br />2. Mark four holes for screws. <br />3. Drill the four holes. <br />4. Install Stopper over detector with four <br />screws and clips provided. <br /> <br />SURFACE-MOUNTED <br />1. Center spacer (Part No. STI 8101) over <br />smoke detector and conduit. <br />2. Mark four holes for screws. <br />3. Drill the four holes. <br />4. Install Stopper over detector using <br />screws and stand-off spacer (Part <br />#8110). <br /> <br />TO SERVICE DETECTOR <br /> <br />Loosen three screws and swing Stopper <br />away. <br /> <br />Tamper proof screws (STI <br />8102 - 2" & STI 8104 - 4") <br />available for mounting_ <br /> <br />STI 9601/9609 <br />REV 10/94 <br /> <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.