Laserfiche WebLink
<br />I <br /> <br />A <br /> <br />05-30347.02 <br />Page 4 of 5 <br /> <br />Test Results: (ContInued) <br /> <br />paragraph <br />2,1.2 <br /> <br />Title or Test - Test Method Results <br />Air Infiltration pet ASTh1 E 283 <br />@ l;S~ psf(2S mpb) 0.11 cfm/ft2 <br /> <br />Allowed <br /> <br />0.3 c1inl~ max, <br /> <br />Note #1' The tested specimen meets the performance levels specified i"n AA.i'IJA./NWWDA. <br />1 OllIS. 2-P7 for. air infiltration. . <br /> <br />2.1.3 <br /> <br />2.1.4 2 <br /> <br />2.2.1.6.2 <br /> <br />2.1,7 <br /> <br />Water Resistanc~ per ASTM E 547 <br />(wi~ and without screen) <br />WtP = 2.86 psI . No leakage <br /> <br />No leakage <br /> <br />Un1fonn Load Structural per ASTM E 330 <br />(Measurements reported were taken on the exterior meeting' stile) <br />@225psf(positive) 0.035" 0.187" max. <br />@22.5 psf(negative) 0.024" 0.187" max. <br /> <br />Deglazing Test per ASTM E 987 <br />Left Sash <br />In operating direction at 70 Ibs <br />Handle stlle O.060"i12% 0.500"/100% <br />Meeting stile o 060"/12% 0,500"/100% <br />In remainmg direction at 50 lbs <br />Top rail 0,,060"/12% 0.500"/1 O()% <br />Bottom raIl 0.060"/12% 0,500"/100% <br />Right Sash <br />In operating dIreCtiOn at 70 lbs <br />Handle stile 0.030"/6% 0.500"/100% <br />Meeting stile 0,060"/12% 0.500"/100% <br />In remalnmg direction at 50 Ibs <br />Top rall 0,090"/18% 0500"1100% <br />Bottom rail o 030"/6% 0500"/100% <br />Welded Comer Test Meets as stated Meets as stated <br />