My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2609
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2609
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:05:48 PM
Creation date
1/16/2007 9:10:14 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-2609
Building Department - Name
WALLACE,JAMES
Address
3524 PERIDOT LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />SECTION 4 <br /> <br />VAPOR BARRIER (OPTIONAL) <br />FOIL BACKED 3/4" OR 1/2" <br />FOAM INSULATION <br /> <br />1/2" x 4'-0" x 8'-0" PRESSBOARD <br />OR COX PLYWOOD <br /> <br />VAPOR BARRIER REQUIRED <br />FOR ALL ADDITIONS EXCEPT <br />SHEDS, 0.006 MIN. VISQUEEN. <br />15# FELT PAPER. THERMAL <br />PLY OR FOIL BACKED <br />INSULATION <br /> <br />VINYL SIDING TYPICAL <br /> <br />FOIL TAPE ALL JOINTS <br /> <br />HEADER AS REQUIRED FOR <br />PAN (FOR HEADER SIZES SEE <br />TABLE 4.3) <br /> <br />STRUCTURES WITH WOOD FRAME WALLS <br />& ALUMINUM ROOF SYSTEMS <br /> <br />-- <br /> <br />DOUBLE 2 x 4 TOP PLATE IF <br />OVER 16' IN PROJECTION OR <br />LENGTH <br /> <br />2- 2"x_" WI 1/2" SPACER <br />(SEE TABLE 4.3) <br /> <br /> <br />NOTES: 1. SIDING IS TO BE FASTENED @ 16" O.C. TO MANUFACTURERS SPECIFICATIONS AND <br />INSTRUCTIONS AS SUPPLIED BY THIi..SIDING COMPANY <br />2. NAILING SIDING OVER FURRING~'OlTp$: 1" SHANK ALUMINUM NAILS OR EQUAL <br />SIDING OVER FOAM: 1-3/4" SHANK ALUMINUM NAILS OR EQUAL <br />3. IF PLYWOOD IS USED FOR CORNER BRACING WITH FOIL BACKED FOAM BEING USED <br />FOR THE VAPOR BARRIER, VISQUEEN,. TAR PAPER OR SOME OTHER SUITABLE <br />PRODUCT MUST BE USED OVER THE WOOD <br />4. IF A FOURTH FRAME WALL IS REQUIRED, ALL FRAMING AND BRACING SHALL BE THE <br />SAME AS FOR OTHER WALLS OR PROVIDE ALUMINUM OR WOOD BEAM SUPPORT WALL <br />5. SIDING SHALL BE APPLIED PER MANUFACTURERS SPECIFICATIONS FOR WIND ZONE <br />OR PROJECT AND OVER PROPERLY PREPARED WALL WITH BRACING OR SHEATHING <br />6. BRACING FOR CORNERS SHALL BE 1/2" 4 PLY COX PLYWOOD FOR WOOD STUDS @ 24" <br />O.C. NAILED WITH #8d COMMON 6" O.C. EDGES AND 12" O.C. FIELD <br />7. ALTERNATE BRACING SHALL BE 1-1/4" x 14 GA. GALVANIZED COIL STRAP X-BRACED TO <br />STUDS WI (1) #8d COMMON PER STUD OR 1-1/4" x 0.050" ALUMINUM STRAP X-BRACED <br />AND NAILED TO STUDS WI (l~tjL4" ALUMINUM NAILS EACH STUD <br />8. STRUCTURAL GRADE TH~fJ_,LY OVER STUDS SHALL BE 16" O.C. AND NAILING OR <br />SCREW PATTERN SAME AS ~WITH NAILS OR SCREWS PER MANUFACTURERS <br />SPECIFICATIONS '. . <br />9. THESE SPECIFICATIONS MAY BE USED FOR FRAMING IN OPENINGS IN EXISTING <br />STRUCTURES. <br /> <br />TYPICAL WOOD FRAME ATTACHED TO HOST STRUCTURE <br /> <br />SCALE: 3/16" = 1'-0" <br /> <br />-.-. <br /> <br />~~.., <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER. DEVELOPMENT CONSUL T ANT <br />P.O. BOX 214368, SOUTH DAYTONA. FL 32121 <br />TELEPHONE (386) 7674774 <br />FAX (386) 767-6556 <br /> <br />PAGE <br /> <br />'- <br /> <br />@ COPYRIGHT 2003 <br />4-2 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E BENNETT, PE <br /> <br />. . <br />
The URL can be used to link to this page
Your browser does not support the video tag.