<br />FORM 600A-2001 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: · · · <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC,1,1 Maximum:,3 cfm/sa.ft. window area' ,5 cfmlsa.ft. door area, <br />Exterior & Adjacent Walls 606.1.ABC,1.2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the too olate. <br />Floors 606.1,ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter oenetrations and seams, <br />Ceilings 606.1.ABC ,1 .2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the oerimeter at oenetrations and seams, <br />Recessed Lighting Fixtures 606.1 ,ABC,1 ,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br /> conditioned soace tested, <br />Multi-storv Houses 606.1,ABC.1.2.5 Air barrier on oerimeter of floor cavitv between floors. <br />Additional Infiltration reqts 606.1.ABC.1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences,) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit <br /> breaker (electric) or cutoff (cas) must be orovided. External or built-in heat trao reauired, <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiencv of 78%. <br />Shower heads 612,1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG. <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min, insulation, <br />HVAC Controls 607,1 Seoarate readilv accessible manual or automatic thermostat for each sYStem, <br />Insulation 604,1, 602.1 Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides, <br /> Common ceiling & floors R-11. <br /> <br />I:norn,,f'':!-Allna™ nr4 I=nrrn ~4_?fV\1 <br /> <br />t:n.o.r",/~'!:III"atfi\/I:'I'!:II:)t:C:I~tv\1 ~I QrOI:l ,,t::l ~n <br />