Laserfiche WebLink
<br />FORM 600A-2001 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br /> <br />FOR BUILDING CONSTRUCTION <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br />LkvwBspe Builder: G.H.D. <br />Lot #17 Oakcrest Way Permitting Office: <br />Zephyrhills, FL Permit Number: <br />Oakcrest Spec Lot #17 Jurisdiction Number: <br />Central <br /> <br />Project Name: <br />Address: <br />City, State: <br />Owner: <br />Climate Zone: <br /> <br />1. New construction or existing <br />2. Single family or multi-family <br />3. Number of units, if multi-family <br />4. Number of Bedrooms <br />5. Is this a worst case? <br />6. Conditioned floor area (i12) <br />7. Glass area & type <br />a. Clear - single pane <br />b. Clear - double pane <br />c. Tint/other SHGC - single pane <br />d. Tint/other SHGC - double pane <br />8. Floor types <br />a. Slab-On-Grade Edge Insulation <br />b. N/A <br />c. N/A <br />9. Wall types <br />a. Concrete, Int Insul, Exterior <br />b. Frame, Wood, Adjacent <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. Under Attic <br />c. Under Attic <br />11. Ducts <br />a. Sup: Unc. Ret: Unc. AH: Garage <br />b. N/A <br /> <br />New <br />Single family <br />I <br />3 <br />No <br />1269 i12 <br /> <br />163.6 ft> <br />0.0 fj;2 <br />0.0 f12 <br />0.0 i12 <br /> <br />R=O.O, 139.0(p) ft <br /> <br />R=4.2, 883.7 ft2 <br />R=II.O, 240.0 ft2 <br /> <br />R=22.0, 629.0 ft2 <br />R=22.0, 640.0 ft2 <br />R=19.0, 42.0 ft2 <br /> <br />Sup. R=6.0, 100.0 ft <br /> <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 30.5 kBtu/hr <br />SEER: 12.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 30.5 kBtu/hr <br />HSPF: 7.80 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br /> <br />a. Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0.90 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HVAC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF- Whole house fan, <br />PT-Programrnable Thermostat, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />Glass/Floor Area: 0.13 <br /> <br />Total as-built points: 19671 <br />Total base points: 20481 <br /> <br />PAS~~ <br /> <br />I hereby certify that the plans and specifications covered <br />by this calculation are in compliance with the Florida <br /> <br /> <br />Ene~yCode. ~_~~.. <br />PREPARED BY~ . <br />DATE: ~ <br />II hereby certify that this building, as designed, is in <br />comPlian~e w' lorida nergy Code. <br />* \ <br />OWNE ENT. . <br />DATE: II D' <br /> <br /> <br />I I Review of the plans and <br />i <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />I[ this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br /> <br />BUILDING F. ICIAL: jitkl <br /> <br />DATE: D:2-- <br /> <br /> <br />EnergyGauge@ (Version: FLRCNB-31) <br />