My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
04-3113
Zephyrhills
>
Building Department
>
Permits
>
2004
>
04-3113
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:24:25 PM
Creation date
1/31/2007 8:41:34 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
04-3113
Building Department - Name
PIZZA HUT
Address
6548 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />TurboChargerâ„¢ Dimensions <br /> <br /> <br />A <br /> <br />E <br /> <br />D <br /> <br />1-6 <br /> <br />TNR125-060 <br />TNR150-060 <br />TNR200-060 <br />TNR150-100 <br />TNR200-100 <br />TNR250-100 <br />TNR300-100 <br />TNA251-100 <br />TNA301-100 <br /> <br />HANDHOLE 1 <br />CLEANOUT <br /> <br /> <br /> <br /> <br />o <br /> <br />INLET 1 <br /> <br />o <br />t DRAIN <br /> <br />'STD <br />'STD <br />'STD <br />'STD <br />'STD <br />STD <br />STD <br />ASME <br />ASME <br /> <br />125,000 <br />150,000 <br />199,999 <br />150,000 <br />199,999 <br />250,000 <br />300,000 <br />250,000 <br />300,000 <br /> <br /> <br />60 <br />60 <br />60 <br />100 <br />100 <br />100 <br />100 <br />100 <br />100 <br /> <br />GAS CONNECTION <br /> <br />AIR INTAKE <br /> <br />3/4" NPT T&P <br />RELIEF VALVE <br /> <br />ALTERNATE <br />INLET CONN. <br /> <br />148 <br />178 <br />238 <br />178 <br />238 <br />297 <br />341 <br />297 <br />341 <br /> <br /> <br />G <br /> <br />TOP VIEW <br /> <br />Maximum Vent Lengths: <br />3" Vent (PVC, CPVC or ABS) <br />TNR 125-060 = 120 Equivalent Ft, <br />TNR 150-060 = 100 Equivalent Ft. <br />TNR200-060 = 80 Equivalent Ft, <br />TNR 150- 1 00 = 120 Equivalent Ft. <br />TNR200- 100 = 100 Equivalent Ft. <br />TNR250- 100 = 80 Equivalent Ft, <br />TNR300- 100 = 60 Equivalent Ft, <br /> <br />H <br /> <br />57" <br />57" <br />57" <br />77-3/4" <br />77-3/4" <br />77 -3/4" <br />77-3/4" <br />77-3/4" <br />77-3/4" <br /> <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br /> <br />Notes: · ASME Construction available upon request. Consult factory for details. <br />Gas Connection is 3/4" NPT. <br />Performance data is based on Manufacturer1s test results. <br /> <br />13" <br />13" <br />13" <br />13" <br />13" <br />13" <br />13" <br />]3" <br />13" <br /> <br />42-1/2" <br />42-1/2" <br />42-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br /> <br /> <br />100 <br />Q <br />~ <br />~,.() <br />-v. <br /><)-?- <br /> <br />This heater is a TurboCharger, 100 <br />gallon water heater with Natural gas <br />and 199,999 Btu/hr input. <br /> <br />4" Vent (PVC, CPVC or ABS) <br />TNR 1 25-060 = 170 Equivalent Ft, <br />TNR 150-060 = 150 Equivalent Ft. <br />TNR200-060 = 130 Equivalent Ft, <br />TNR 150- 100 = 170 Equivalent Ft. <br />TNR200- 100 = 150 Equivalent Ft. <br />TNR250-100 = 130 Equivalent Ft, <br />TNR300-100 = 110 Equivalent Ft. <br /> <br />52-1/2" <br />52-1/2" <br />52 -1/2" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br /> <br />53-1/2" <br />53-1/2" <br />53-1/2" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br />7 4-3/4" <br /> <br />40" <br />40" <br />40" <br />60" <br />60" <br />60" <br />60" <br />60" <br />60" <br /> <br />570 <br />570 <br />570 <br />900 <br />900 <br />900 <br />900 <br />900 <br />900 <br /> <br />Model Tank Btu/ hr Gal. GPH @ Shipping <br />Number Const. In ut Ca. 1000F Rise A B D E F G H Wei hi <br /> <br />Change N to L for LP gas models. <br />Water Connections are 1-1/2" NPT. <br /> <br />TurboChargerâ„¢ Typical Specification <br /> <br />The WATER HEATER shall be a LOCHINVAR TURBOCHARGER, Model having an input rating of Btulhr, a recovery <br />capacity of gallons per hour at a lOO"F rise and shall be operated on (Natural Gas)(LP Gas). <br />The tank construction shall be of high strength steel with a triple pass flue design for increased heat transfer efficiency. The tank shall be constructed in <br />accordance with standard construction requirements and shall be designed to withstand a hydrostatic test pressure of two times the working pressure without <br />leakage. The tank shall have a working pressure of 150 psi. The tank shall be furnished with a handhole for ease of inspection, cleanout and service, The <br />interior of the tank shall be glass lined and fired to 1600" F to ensure a molecular fusing of glass and steel. The tank shall be furnished with four magnesium <br />anodes to provide electrolytic protection and shall carry a three (3) year limited warranty. <br />The WATER HEATER shall be constructed with a heavy gauge steel jacket assembly. The tank shall be completely encased in high density polyurethane <br />foam insulation to maximize heat retention and lower standby heat loss, The exterior of the jacket assembly shall be finished with a 3 coat acrylic enamel finish, <br />The WATER HEATER shall be approved for zero clearance to combustible materials. <br />The WATER HEATER shall be equipped with a sealed combustion system for direct venting using PVC, CPVC or ABS. <br />The WATER HEATER shall have an electronic ignition system and an ASME temperature and pressure relief valve. It shall be factory assembled and tested <br />and require no special calibrations or start up. The WATER HEATER shall be approved to provide 180"F water for sanitation, commercial and industrial <br />operation. In the case of an overheat condition the WATER HEATER will employ an energy cut off that shuts off all gas, <br />The entire WATER HEATER shall be certified and listed by C.S.A. International under the latest edition of the ANSI Z21.10.3 test standard for water heaters. <br />The WATER HEATER shall comply with the energy efficiency requirements for standby loss and thermal efficiency as specified in the latest edition of the <br />ASHRAE 90,1 Standard. The WATER HEATER shall be certified and listed in Canada by The Canadian Gas Association under the latest edition of <br />applicable CSA/CGA Standards, <br /> <br /> <br /> <br />'It- · <br /> <br />~ High Effiden,y Wate< Heate". BoUen and Poollle.tm <br /> <br /> <br />e <br /> <br />@ <br /> <br />Lochinvar Corporation' 300 Maddox Simpson Pkwy' Lebanon, TN 37090 . 615-889-8900/ Fax: 615-547-1000 <br />www.Lochinvar.com <br /> <br />TNR-03 <br /> <br />5M - 4/04 - Printed in U.S.A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.