Laserfiche WebLink
<br />TurboCharger'M Dimensions <br /> <br /> <br />OUTLETl <br />o <br /> <br />A <br /> <br />E <br /> <br />HANDHOLE 1 <br />CLEAN OUT 1 <br /> <br /> <br /> <br />o <br /> <br />D <br /> <br />INLET 1 <br /> <br />o <br />L DRAIN <br /> <br />I-B <br /> <br />TNR 125-060 <br />TNR150-060 <br />TNR200-060 <br />TNR150-100 <br />TNR200-100 <br />TNR250-100 <br />TNR300-100 <br />TNA251-100 <br />TNA301-100 <br /> <br />*STD <br />*STD <br />*STD <br />*STD <br />*STD <br />STD <br />STD <br />ASME <br />ASME <br /> <br />125,000 <br />150,000 <br />199,999 <br />150,000 <br />199,999 <br />250,000 <br />300 , 000 <br />250,000 <br />300,000 <br /> <br /> <br />60 <br />60 <br />60 <br />100 <br />100 <br />100 <br />100 <br />100 <br />100 <br /> <br />GAS CONNECTION <br /> <br />AIR INTAKE <br /> <br />3/4" NPT T&P <br />RELIEF VALVE <br /> <br />ALTERNATE <br />INLET CONN. <br /> <br />148 <br />178 <br />238 <br />178 <br />238 <br />297 <br />341 <br />297 <br />341 <br /> <br />H <br /> <br />Notes: * ASME Construction available upon request. Consult factory for details. <br />Gas Connection is 3/4" NPT. <br />Performance data is based on Manufacturer's test results. <br /> <br /> <br />G <br /> <br />F <br /> <br />TOP VIEW <br /> <br />Maximum Vent Lengths: <br />3" Vent (PVC, CPVC or ABS) <br />TNR 125-060 = 120 Equivalent Ft, <br />TNR 150-060 = 100 Equivalent Ft. <br />TNR200-060 = 80 Equivalent Ft. <br />TNR 150- 100 = 120 Equivalent Ft. <br />TNR200- 100 = 100 Equivalent Ft. <br />TNR250-100 = 80 Equivalent Ft. <br />TNR300-100 = 60 Equivalent Ft. <br /> <br />57" <br />57" <br />57" <br />77 -3/4" <br />77-3/4" <br />77 -3/4" <br />77-3/4" <br />77-3/4" <br />77-3/4" <br /> <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br />28-1/4" <br /> <br />13" <br />13" <br />13" <br />13" <br />13" <br />13" <br />13" <br />13" <br />13" <br /> <br />42-1/2" <br />42-1/2" <br />42-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br />62-1/2" <br /> <br /> <br />100 <br />% <br />CV'" <br />-v. <br />o~ <br /> <br />This heater is 0 TurboCharger, 100 <br />gallon water heater with Natural gas <br />and 199,999 Btu/hr input, <br /> <br />52-1/2" <br />52-1/2" <br />52-1/2" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br />73-1/4" <br /> <br />4" Vent (PVC, CPVC or ABS) <br />TNR 125-060 = 170 Equivalent Ft. <br />TNR 150-060 = 150 Equivalent Ft, <br />TNR200-060 = 130 Equivalent Ft. <br />TNR 150-1 00 = 170 Equivalent Ft. <br />TNR200- 1 00 = 150 Equivalent Ft, <br />TNR250- 100 = 130 Equivalent Ft. <br />TNR300- 1 00 = 110 Equivalent Ft. <br /> <br />53-1/2" <br />53-1/2" <br />53-1/2" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br />74-3/4" <br /> <br />40" <br />40" <br />40" <br />60" <br />60" <br />60" <br />60" <br />60" <br />60" <br /> <br />570 <br />570 <br />570 <br />900 <br />900 <br />900 <br />900 <br />900 <br />900 <br /> <br />Model Tank Btu/ hr Gal. GPH @ Shipping <br />Number Const. In ut Ca. lOooF Rise A B D E F G H Wei ht <br /> <br />Change N to L for LP gas models. <br />Water Connections are 1-1/2" NPT. <br /> <br />TurboCharger'M Typical Specification <br /> <br />The WATER HEATER shall be a LOCHINV AR TURBOCHARGER, Model having an input rating of Btulhr, a recovery <br />capacity of gallons per hour at a 100"F rise and shall be operated on (Natural Gas)(LP Gas). <br />The tank construction shall be of high strength steel with a triple pass flue design for increased heat transfer efficiency. The tank shall be constructed in <br />accordance with standard construction requirements and shall be designed to withstand a hydrostatic test pressure of two times the working pressure without <br />leakage. The tank shall have a working pressure of 150 psi, The tank shall be furnished with a handhole for ease of inspection, cleanout and service, The <br />interior of the tank shall be glass lined and fired to 1600" F to ensure a molecular fusing of glass and steel. The tank shall be furnished with four magnesium <br />anodes to provide electrolytic protection and shall carry a three (3) year limited warranty. <br />The WATER HEATER shall be constructed with a heavy gauge steel jacket assembly. The tank shall be completely encased in high density polyurethane <br />foam insulation to maximize heat retention and lower standby heat loss. The exterior of the jacket assembly shall be finished with a 3 coat acrylic enamel finish. <br />The WATER HEATER shall be approved for zero clearance to combustible materials. <br />The WATER HEATER shall be equipped with a sealed combustion system for direct venting using PVC, CPVC or ABS. <br />The WATER HEATER shall have an electronic ignition system and an ASME temperature and pressure relief valve. It shall be factory assembled and tested <br />and require no special calibrations or start up. The WATER HEATER shall be approved to provide l80"F water for sanitation, commercial and industrial <br />operation, In the case of an overheat condition the WATER HEATER will employ an energy cut off that shuts off all gas. <br />The entire WATER HEATER shall be certified and listed by C.S.A. International under the latest edition of the ANSI Z21.1 0.3 test standard for water heaters. <br />The WATER HEATER shall comply with the energy efficiency requirements for standby loss and thermal efficiency as specified in the latest edition of the <br />ASHRAE 90,1 Standard, The WATER HEATER shall be certified and listed in Canada by The Canadian Gas Association under the latest edition of <br />applicable CSNCGA Standards. <br /> <br /> <br /> <br />.Lochinwr' <br /> <br />~ High Efficienq' Water Heaten, Boilers and Pool Heaten <br /> <br />8 <br /> <br />@ <br /> <br />Lochinvar Corporation. 300 Maddox Simpson Pkwy. Lebanon, TN 37090 . 615-889-8900 / Fax: 615-547-1000 <br /> <br />www.Lochinvar.com <br /> <br />TNR-03 <br /> <br />5M - 4/04 - Printed in U.s.A. <br />